Maintenance ■ The Laser Module and Shuttle
- 126 -
Data I/O ■ 096-0465-001C
3.
Wipe the shuttle tips with a damp cloth—soapy water is okay. (Do
NOT use alcohols or solvents.)
Laser Marking Fume Extractor
[
Laser Marking
only] All models with Laser Marking have a fume
extractor. The fume extractor requires some attention as described
below.
S
TART
-
UP
CAUTION: Possible health hazard! Dust from the main filter may be
expelled on start-up after PSV5000 transportation. Turn the system ON in a room
with appropriate ventilation or wear dust respirator and goggles.
The Fume Extractor starts automatically when the PSV500 Machine is
started (unless the extractor has been manually turned off).
WARNING: Possible health hazard! Lased materials can
contain hazardous toxins in the dust that cause eye and skin damage! DO
NOT use compressed air to remove laser dust or any method that allows the
particulate to be released into the work environment. Wear safety goggles
and disposable protective gloves.
C
LEANING THE
L
ASER
M
ODULE AND
F
UME
E
XTRACTOR
T
UBE
The filter extraction tube should be cleaned occasionally for best flow.
Contact Data I/O Customer Support or a local Data I/O approved service
representative.
WARNING: Health hazard! Failure to replace the laser vacuum filters
at the required intervals could create a hazardous operating environment.
WARNING: Hazardous Materials—Possible health hazard!
This procedure involves exposure to hazardous by-products from the laser
marking process. Some device material may be carcinogenic.
Summary of Contents for PSV5000
Page 12: ......
Page 36: ......
Page 160: ......
Page 161: ...Electrical Schematics for PSV5000 and Equipment ...
Page 162: ......
Page 163: ......
Page 164: ......
Page 165: ......
Page 166: ......
Page 167: ......
Page 168: ......
Page 169: ......
Page 170: ......
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ...PROGRAMMABLE MEDIA EXPERTS ...