Pick and Place Probe
Replacing the Input Air Filter
PSV5000 Owner’s Manual
- 107 -
Figure 63:
The PNP Probe vacuum generator adjustments. (Looking
in from the back of the machine) the vacuum generator faces up.
The green lamp (arrow) is currently off.
7.
Read the high and low values each time you plug the air with your
finger and release it. They are needed for the next step.
8.
Set the trigger value on the sensor by pressing the S (blue SET)
button on the vacuum generator block and then using the UP or
DOWN buttons, set the value to midway between the high value and
the low value. It should be approximately -40 kPa.
9.
Press the SET button again.
10.
Check adjustment by blocking and unblocking the probe tip several
times and ensuring the green lamp goes on and off each time.
11.
Repeat these steps for probe 2.
12.
Turn OFF the vacuum switch for the probe.
Wipe the probe tip with a clean dry cloth.
Replacing the Input Air Filter
1.
If a job is running, Pause or Finish the job.
2.
Turn off shop air and disconnect the input air line from the Air
Filter/Regulator at the quick connect fitting.
3.
Unscrew the air contamination collection bowl housing.
4.
Pull off the clear collection bowl. Clean out any dirt, oil, or water.
5.
Unscrew the black knob below the filter.
6.
Pull off the filter. Clean or replace as necessary.
Summary of Contents for PSV5000
Page 12: ......
Page 36: ......
Page 160: ......
Page 161: ...Electrical Schematics for PSV5000 and Equipment ...
Page 162: ......
Page 163: ......
Page 164: ......
Page 165: ......
Page 166: ......
Page 167: ......
Page 168: ......
Page 169: ......
Page 170: ......
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ...PROGRAMMABLE MEDIA EXPERTS ...