5. Replacing the carbon brushes
(1) Loosen the screws (2) for the chuck cover, then
remove the chuck cover from the housing. (
Fig. 17
,
Fig. 18
)
(2) Pinch the terminals for the carbon brushes with
pliers, then pull them out of the brush holder. (
Fig.
19
)
(3) Pull the springs forward with a Phillips screwdriver,
then remove the carbon brushes. (
Fig. 20
)
(4) Reverse these procedures to install the brushes.
6. Cleaning on the outside
When the power tool is stained, wipe with a soft
dry cloth or a cloth moistened with soapy water.
Do not use chloric solvents, gasoline or paint thinner,
as they melt plastics.
7. Storage
Store the power tool in a place in which the
temperature is less than 40°C and out of reach of
children.
8. Service parts list
CAUTION
Repair, modification and inspection of Power Tools
must be carried out by an Authorized Service Center.
This Parts List will be helpful if presented with the
tool to the Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools,
the safety regulations and standards prescribed in
each country must be observed.
MODIFICATIONS
Power Tools are constantly being improved and
modified to incorporate the latest technological
advancements.
Accordingly, some parts may be changed without
prior notice.
NOTE
Due to DATACOL’s continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT:
Correct connections of the plug
The wires of the mains lead are coloured in accordance
with the following code:
Blue:
-Neutral
Brown:
-Live
As the colours of the wires in the mains lead of this tool
may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Neither core must be connected to the earth termninal.
NOTE:
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markers except United Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN50260 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 103 dB (A)
Measured A-weighted sound pressure level: 92 dB (A)
Uncertainty KpA: 3 dB (A).
Wear ear protection.
The typical weighted root mean square acceleration
value: 6.7 m/s
2
.