7.5 eMail Notifications
DS-1010 provides an Email Notifications function which initiates an email notification upon switching mode
of an I/O segment. The mail server and email account settings can be configured through the Web
management or CLI interface.
Figure 20. eMail Notifications
Figure 20. eMail Notifications
, shows the email
notification options which need to be filled
properly by the system administrator to enable or
disable the email notification function and
configures the email servers and accounts.
7.6 SNMP Settings
DS-1010 provides SNMP Trap function which can send messages to a destination IP when the I/O
segment status or Power Supply status is changed.
Figure 21. SNMP Settings
,
shows the
SNMP options setting which enables or
disables the SNMP Trap function and
configures the SNMP destination IP and
SNMPv2 community name.
Figure 21. SNMP Settings
7.7 NTP Settings
Figure
22. NTP Settings
Figure 22. NTP Settings
,
shows the Network
Time Protocol (NTP) options setting which
enables or disables synchronizing the computer
system clock over packet-switched, variable-
latency data networks. NTP uses UDP on port
123 as its transport layer. It is designed
particularly to resist the effects of variable latency
by using a jitter buffer.