VS-1200 Data Acccess Switch
52
© 2009 Datacom Systems Inc
IMPORTANT:
Fiber taps are not capable and
CAN NOT
auto-negotiate link with the
VS-
1210SFP
ports and
MUST BE
be hard set to 1,000 Mbs and full-duplex.
Port 1, 2, 3, and 4's is set to 1,000 Mbs and full-duplex with this syntax:
# SET PORT SPEED 1,2,3,4 1000FULL
Now
you can begin setting the ports as to which port inputs the data and which ports
aggregate and/or output the data
.
Port 5 is set as output for Port 1 and 3’s input which is set with this syntax:
# SET PORT MONITOR 5 FROM 1,3
Port 6 is set as output for Port 1 and 3’s input which is set with this syntax:
# SET PORT MONITOR 6 FROM 1,3
Port 7 is set as output for Port 2 and 4’s input which is set with this syntax:
# SET PORT MONITOR 7 FROM 2,4
Port 8 is set as output for Port 2 and 4’s input which is set with this syntax:
# SET PORT MONITOR 8 FROM 2,4
Port 9 is set as output for Port 1, 2, 3 and 4’s input which is set with this syntax:
# SET PORT MONITOR 9 FROM 1,2,3,4
Port 10 is set as output for Ports 4’s input which is set with this syntax:
# SET PORT MONITOR 10 FROM 4
CONCLUSION:
The VS-1210BT/SFP provides the ability to aggregate data streams from TAPs.
Aggregating streams together improves overall visibility for the tools and permits specific
departmental devices to only see the traffic they need. The VS-1210SFP allows many devices to
share a single output. The VS-1210SFP Small Form Pluggable capacity, allows users to send data
across multimode, single-mode fiber or copper.