LANcat
User Manual
Page 7-34
1.
When connecting to unidentified twisted pair cable, ensure there
are no voltages on the segment. Use a tone tester or voltmeter to
determine that there are no voltages on the wire.
2.
Connect the remote unit to one end of the cable. Connect the
main unit to the other end.
SELECTING THE PROPER TEST
Autotest should be used for all certification testing. Autotest
verifies all twisted pair cable parameters meet the requirements of
the cable specification selected. Autotest is also the only test other
than Ethernet Traffic that can be saved for later printing.
The purpose of the Quick Check is to ensure there are no gross
errors before running the longer Autotest. If there is a gross error
(for example, split pair, OPEN, segment too long), you can fix the
error before running the extended certification test, thus saving
time.
You cannot use the Quick Check for certification testing because it
does not make all the measurements necessary to ensure EIA/TIA
compliance. The Quick Check was only designed as a quick test.
When testing UTP segments, the EIA/TIA Link Performance
standard requires that you test NEXT from both directions.
Because the link is not end-for-end symmetrical, NEXT will be
different on each end. By testing from both directions, you can
ensure no cable faults were missed.
If you suspect that you have a noise problem, check it from both
ends of the cable.