4.
Connect a known length of sample cable to the LANcat. The
cable must be at least 50 feet (15 meters) long to get an
accurate measurement (longer lengths improve accuracy).
Leave the far end of the cable open.
5.
Press START(F1).
6.
Press DEC (F2) or INC (F3) to adjust the cable length on
the display to the known cable length.
7.
Press SAVE (F4) or ENTER to save the new value.
8.
To repeat, press Start (F1).
9.
Press ESC to exit the NVP calibration mode.