LANcat
User Manual
Page D-8
wired up a 568B cable as a 568A or visa versa. Swap the
Orange and Green pairs. See Table 1.)
Recalibration
1. CALIBRATE PERFORMANCE MODULE
Follow the procedures in Chapter 9 of the LANcat Series User
Manual for Performance Module Calibration.
NOTE
In addition to calibrating, this step checks the NEXT
to ensure that your new cable assembly is similar in
quality to Datacom Textron factory specifications. If
your assembly fails this test, re-examine the twisted
pairs as they enter the screw terminals. Try twisting
the wires tighter and make sure the twists extend as
close as possible to the screw terminals. Sometimes
moving the pairs is all that is required. Many CAT 5
patch cables have too much NEXT due to the way
they are terminated at the plug end. You may need to
try several before finding one that passes this test.
Pre-tested cables are available from your Datacom
Textron Representative or directly from Datacom
Textron.