Appendix A
Test Standards
Page A-13
Table 11. 100 Base TX Pass/Fail Limits
Length
≤
100 meters
Characteristic
Impedance
100 + 25
Ω
NEXT
Between 1 and 100 MHz,
NEXT > Category 5 Channel
Limits
Attenuation
Between 1 and 100 MHz,
Attenuation < Category 5 Channel
Limits
Split Pair
NEXT < 20 dB (8 - 10 MHz)
Resistance
< 9.9
Ω
Table 12. 100 Base T4 Pass/Fail Limits
Length
≤
100 meters
Characteristic
Impedance
100 + 25
Ω
NEXT
Between 1 and 16 MHz,
NEXT > Category 3 Channel
Limits
Attenuation
Between 1 and 16 MHz,
Attenuation < Category 3
Channel Limits
Split Pair
20 dB
Resistance
< 9.9
Ω