5 DM-SV01 Maintenance
This section describes the procedures and guidelines to install the server and also to provide basic
maintenance, such as the assembling or replacement of sub-modules and mechanical components.
5.1 Air Duct
The DM-SV01 server is covered by a plastic air duct. The air duct protects the processors and DDR
memories and it is designed for efficiently guiding the airflow in order to refrigerate such components.
The insertion and removal of the air duct can be accomplished by following the procedures below.
● To remove the air duct, slide it to the front until it is mechanically released (step 1) and then pull
it up (step 2).
Figure 57: Air Duct removal
● To insert the air duct, pull it down with the metal guiding pins aligned to the plastic openings
(step 1 and detail in Figure 58) and then move it backwards until it locks and attaches to the
mechanics (step 2).