Environmental Requirements & Specifications
96-30065-001 Rev. A0
DataDirect Networks EF4024 FC RAID System Setup Guide | 58
1
Weights shown are nominal, and subject to variances.
2
Rail kits add between 2.8 kg (6.2 lb) and 3.4 kg (7.4 lb) to the aggregate enclosure weight.
3
Weights may vary due to different power supplies, IOMs, and differing calibrations between scales.
4
Weights may vary due to actual number and type of disk drives and air management modules installed.
B.4
Environmental Requirements
Operating Environmental
*Temperature is de-rated by 2ºC (3.6ºF) for every 1 km (3,281) feet above sea level.
Non-Operating Environmental
Table 12. Rackmount Controller Enclosure Weights
Configuration
Weight
Controller enclosure
• Chassis only
•
Chassis with FRUs (no disks)
1-3
•
Chassis with FRUs (including disks)
1-4
• 8.6 kg (19.0lb)
• 17.4 kg (38.4 lb)
•
23.4 kg (51.6 lb)
Expansion enclosure
• Chassis only
•
Chassis with FRUs (no disks)
1-3
•
Chassis with FRUs (including disks)
1-4
• 8.6 kg (19.0 lb)
• 16.2 kg (35.8 lb)
•
22.2 kg (49.0 lb)
Specification
Range
Altitude
To 3,000 meters (9,843 feet )
Temperature*
5ºC to 40ºC (41ºF to 104ºF)
Humidity
10% to 90% RH up to 40ºC (104ºF) non-condensing
Shock
3.0
g,
11
ms, ½ sine pulses, X, Y, Z
Vibration (Shaped-spectrum)
5 Hz to 500 Hz, 0.14
Grms total X, Y, Z
Specification
Range
Altitude
To 12,000 meters (39,370 feet)
Temperature
-40ºC to 70ºC (-40ºF to 158ºF)
Humidity
Up to 93% RH @ 104ºF (40ºC) non-condensing
Shock
15.0
g,
11
ms, ½ sine pulses, X, Y, Z
Vibration (Shaped-spectrum)
2.8 Hz to 365.4 Hz, 0.852
Grms total (horizontal)
2.8 Hz to 365.4 Hz, 1.222
Grms total (vertical)