90
D a t a D i r e c t N e t w o r k s S 2 A 9 5 5 0 U s e r G u i d e
S 2 A 9 5 5 0 M e s s a g e s a n d D e s c r i p t i o n s
in the array. Timeout messages may also be generated under heavy I/O conditions or when an error
occurs like a disk failure or a LIP on the Fibre Channel bus. Timeouts should generally not occur
during normal operation and should be reported if they keep reappearing.
4.2.4
Informational Messages
All other system messages are used to inform the operator of a change in the system status. These
messages do not indicate a problem with the S2A9550 but may indicate a problem that requires user
intervention.
Failing Disk 1A
Replacing Failed Disk 1A with Spare Disk 1S
All informational messages that are related to an I/O command from an initiator will be displayed
with the initiator information. This will include the initiator’s 64-bit World Wide Name, the host port
the initiator is communicating on, the source ID the initiator is using on the Fibre Channel bus, and
the exchange ID of the SCSI command (see following example).
Read Address error LUN:0 address:80000000 length:1
WWN:2000000011111111 port:4 S_ID:10 OX_ID:4189
4.2.5
SDRAM and Cache Error Messages
Warning: SDRAM not detected on disk channel A, slot 0.
Warning: SDRAM not detected on disk channel A, slot 1.
The above messages indicate that the S2A9550 cannot locate the SDRAM on the disk channel. The
SDRAM should be installed in slot 0 of each disk channel. If the SDRAM is installed in slot 1 on one
channel, then all the other channels must have the SDRAM installed in slot 1 as well. This error will
prevent the system from running normally. Make sure the SDRAM is installed correctly.
Warning: SDRAM configuration mismatch detected on channel A, slot 0.
Warning: SDRAM configuration mismatch detected on channel A, slot 1.
The above messages indicate that there is a mismatch on the SDRAM configurations. The S2A9550
requires that all the SDRAM installed have the same size, configuration and speed. This error will
prevent the system from running normally. Make sure the SDRAM is installed correctly.
Warning: Cache diagnostic failure on host port 1.
Warning: Cache diagnostic failure on disk channel A.
The above messages indicate that the S2A9550 performed a diagnostic test on the SDRAM from the
host and disk sides and discovered an error. This error will prevent the system from running
normally. Make sure the SDRAM is installed correctly.
Warning: Unknown cache diagnostic status on host port 1.
Warning: Unknown cache diagnostic status on disk channel A.
The above messages indicate that the SS2A9550 performed a diagnostic test on the SDRAM from the
host and disk sides and discovered an error with the test itself. This error will prevent the system
from running normally. This may indicate a problem with the firmware.
Timeout: Cache diagnostic host port 1.
Timeout: Cache diagnostic disk channel A.
The S2A9550 performed a diagnostic test on the SDRAM from the host and disk sides but the test took
too long to complete. This error will prevent the system from running normally. This may indicate a
problem with the hardware.
Summary of Contents for S2A9550
Page 1: ...DataDirect Networks Silicon Storage Appliance S2A9550 User Guide Rev 4 0 ...
Page 13: ...SECTION 1 Introducing the S2A9550 ...
Page 14: ...This page intentionally left blank ...
Page 21: ...SECTION 2 Installing the S2A9550 ...
Page 22: ...This page intentionally left blank ...
Page 24: ...Installation 12 DataDirect Networks S2A 9550 User Guide This page is intentionally blank ...
Page 43: ...SECTION 3 Using the S2A9550 Management Administrative Facilities ...
Page 44: ...This page intentionally left blank ...
Page 93: ...SECTION 4 Supporting the S2A9550 ...
Page 94: ...This page intentionally left blank ...
Page 113: ...SECTION 5 Appendices ...