4
D a t a D i r e c t N e t w o r k s S 2 A 9 5 5 0 U s e r G u i d e
I n t r o d u c i n g t h e S 2 A 9 5 0 0
•
High-Parallel Port Technology Implementation
HPPT architecture provides system performance and fault-tolerance.
- 10-independent dual-ported FC drive channels; including separate (asynchronous, “self-optimized”)
I/O queues for each channel
- 10-independent directRAID engines
- 10-independent RAID-protected high speed data caches
•
Highly Scalable Performance and Capacity
The directRAID engine provides both fault-tolerance and capacity scalability. Performance will remain
the same even in degraded mode. Internal data striping provides generic load balancing across drives.
Formattable capacity can be scaled from 584 GB to 730 TB (336 TB, 300GB drives with SFx016 enclosures
and 448TB, 400GB drives with SAx016 enclosures).
•
Comprehensive, Centralized Management Capability
The S2A9550 provides a wide range of management capabilities: Configuration Management,
Performance Management, LUN Management, Security Administration, and Firmware Update
Management.
•
Management Options via RS-232 and Ethernet (Telnet)
A RS-232 port and Ethernet port are included to provide local and remote management capabilities.
SNMP and GUI are also supported.
•
Data Security with Dual-Level Protection
Non-host based data security is maintained with scalable security features including restricted
management access, dual-level protection and authentication against authorized listing (up to 512 direct
host logins are supported). No security software is required on the host computers.
•
Storage Virtualization and Pooling
Storage pooling enables different types of storage to be aggregated into a single logical storage resource
from which virtual volumes can be served up to multi-vendor host computers. Up to 128 LUNs are
supported. Each LUN can be subdivided into up to 64 smaller equally-sized LUN segments, giving a total
of 8192 LUN segments. The LUN segments of a LUN are managed together and share the same
characteristics.
•
SES (SCSI Enclosure Services) Support for Enclosure Monitoring
Status information on the condition of enclosure, disk drives, power supplies, and cooling systems are
obtained via the SES interface.
•
Absolute Data Integrity and Availability
Automatic drive failure recovery procedures are transparent to users. Up to
125 hot spares
are
supported.
•
Hot-Swappable and Redundant Components
The S2A9550 utilizes redundant, hot-swappable power supplies and cooling modules that can be
replaced while the system is running.
Summary of Contents for S2A9550
Page 1: ...DataDirect Networks Silicon Storage Appliance S2A9550 User Guide Rev 4 0 ...
Page 13: ...SECTION 1 Introducing the S2A9550 ...
Page 14: ...This page intentionally left blank ...
Page 21: ...SECTION 2 Installing the S2A9550 ...
Page 22: ...This page intentionally left blank ...
Page 24: ...Installation 12 DataDirect Networks S2A 9550 User Guide This page is intentionally blank ...
Page 43: ...SECTION 3 Using the S2A9550 Management Administrative Facilities ...
Page 44: ...This page intentionally left blank ...
Page 93: ...SECTION 4 Supporting the S2A9550 ...
Page 94: ...This page intentionally left blank ...
Page 113: ...SECTION 5 Appendices ...