Connecting the IO-Box:
Anschluss (ST1,2,3)
Klemme Nr. Beschreibung
ST1
1
Relais 1
normally close
2
Relais 1
common
3
Relais 1
normally open
4
free
5
free
6
digital in 1 Signal
7
digital in 1 ground
ST2
1
Relais 2
normally close
2
Relais 2
common
3
Relais 2
normally open
4
free
5
free
6
digital in 2 Signal
7
digital in 2 ground
ST3
1 und 2
ground
3
U+ 8…..30V
4
SCL
5
SDA
ST 1
Circuit diagram
3
=
“S“ normally open
2
=
“G“ common
1
=
“Ö“ normally close