5.7.20.3. Remarks
• A radio lock may only have one office mode assigned: You may either use the secure variant
(with a big elapse time) or the classic mode.
• If an ID card is set to “Active General” 6, an elapse time bigger than 3 seconds may be set.
• Revoking classic office mode requires identification with the same ID card twice within the
office mode repetition interval:
o
Activating or deactivating the classic office mode requires that
– after the first identifi-
cation
– the elapse time has to have passed.
Reason for this is that while the door relay is set (which it is during the elapse time),
the communication of the radio door control unit is paused as well as its reading of ID
cards.
• If a permanent-open ID card is restricted in time, activating the classic office mode is possi-
ble only during the restricted time.
• Deactivating classic office mode is possible at any time using a permant-open ID card –
even outside the restricted time of the ID card.
• If classic office mode is active, the door feedback – indepently of the validity of the ID card –
is always green
– the door is currently opened.
• Due to the radio locks being battery powered, LED feedback is possible only directly after
operating the radio lock.
• After activating the classic office mode and a subsequent restart of the access controller, the
door may be used once without prior identification. Then the radio lock decouples and the
door is locked.
o
Background: The first operation of the radio lock (reading an ID card or operating a
door knob) after restarting the access controller will set the radio lock it its default
state.
o
After setting the radio lock to its default state it is in state “classic mode inactive” –
the LEDs will signal accordingly.
Summary of Contents for KYO Inloc