3.6.1 Communication via RS232
3.6.1.1 Requirement
For a communication with a PZE-MasterIV Basic over an RS-232 connection, the device has to be set for
this communication in the system menu-BIOS (see chapter
). Furthermore, baud rate and timeout
of the RS232-interface of the terminal and the PC must be coordinated. Permitted baud rates are 9600,
19200 and 38400. The timeouts have to be between
100
and
2000
. When you select RS232 for
communication the timeout is set on 100 by default.
3.6.1.2 Connection
A single device can be connected to the
PC directly via the RS232-interface (po-
sition
2
in figure
). The cable must not
be longer than 15 m. Use a RS232 cable
with a 1:1 configuration, corresponding
to Datafox item no. 20010, as connect-
ing cable.
Figure 9: Connection of the PZE-MasterIV Basic with the PC about RS232