Manual Datafox PZE-MasterIV Basic
5.2 Functions of a setup
5.2.1 Basic settings
Note:
With the DatafoxStudioIV more than one device type can be configured. The
functionality of the devices differs. Therefore it is important to select the device
type at first. Only then it can be guaranteed that all functions are available while
configuring and that they are not deactivated.
Depending on the chosen communication type some further settings have to be carried out. Please note,
that all changes have to go well with the settings of the device (see chapter
After setting the type of device and communication the basic settings, the global variables and the
transponder settings of the device can be defined.
1
2
3
Activating the online operation is combined with
a wait (input lock) after each input (booking
record), for the set period of time in ms.
Under Device settings the display and the acoustics
are defined. In order to secure the configuration,
you can set up a password for the system menu-
BIOS (see chapter
Bios).
Figure 48: Basic settings depending on the device
The operating mode controls the reactions when you enter something. If Normal is selected, the device
dwells on the key that was pressed last. When PZE-Mode 1 is selected, the device returns to the F1-key
after the set period of time (timeout for keyboard shift). The anti-repeat lock for bookings indicates, that
a card is read only once within the set period of time. The PZE-Mode 2 has to be configured via the time
zones additionally.