Manual Datafox PZE-MasterIV Basic
This configuration cannot take place before the
definition of the operation is finished.
The input chains (assigned under operating mode,
with setting of time and activation of weekdays)
are not available till then.
Figure 49: Definition of time zones
Via the time zones the following reactions can be defined:
1.) The device is in operation, but no booking record is carried out over a longer period of time. All
60 seconds the device checks the current operating mode (time and weekday) and sets itself to that
state.
2.) When a key is pressed, e.g. when calling up staff accounts, and the timeout is run out, the device
returns to the state defined via the time zones. This can be the main menu, the last key, the last
key F1-F2 or an input chain.
3.) When a booking record was finished after pressing the
-key, the device returns to the state defined
via the time zones forthwith.
From version 04.01.06. x can be put how much of the device memory should be used for records and how
much for lists.
5.2.2 Global variables
Global variables are used as buffers within the device and do not depend on a data type. That way it
is possible to transmit values, created within an input chain, to another input chain for reprocessing. At
most 8 global variables can be defined in the PZE-MasterIV Basic.
Already while defining, the global variables can be preallocated with values (in the basic settings of the
device via the register card Global variables, see figure
). It is also possible to fill them with values via
input chains within the term. If you access to the same GV repeated, writing, via input chains, the value
of the GV is changed.
When a global variable is filled via an input chain you have to differ to cases: Either you fill the GV and
create a data record concurrently, or you fill the GV without creating a data record. In the second case
please note, that there should be no connection to any data record description.
When inputting GVs using the function Normal, you can carry out a format check via the register card
Expanded. Such a test is not available for other input functions. That is not necessary, because there the
Version: 04.01.07.00
Page
61