Manual Datafox PZE-MasterIV Basic
At most 3 segments are available for concurrent
processing. You can select them in the DatafoxS-
tudioIV under Transponder via the segment
number.
Via the filing format you set how the 32bit-value
is used.
When you select Fixed length the read card value
is cut to the set number of digits and is filled up
with zeros (0) left-sided, if necessary.
Figure 54: Hitag2 transponder
For the writing of the cards an initial value per each segment can be set. You can activate the option
Autoincrement value behind the current initial value. Then the current segment value is increased by the
value indicated under Autoincrement value after every write operation. The initial values of the segments
can be edited in the device-BIOS. The set autoincrement value is only displayed in the device-BIOS and
cannot be changed on the device itself. The writing of cards can be saved by a menu password.
HitagS
When using this method you differ between "‘HitagS H32"’, "‘HitagS H56"’ and "‘HitagS H48"’.
HitagS H32 means, that this transponder has just
a 32bit-value (= serial number of the card) (see
Unique).
Figure 55: HitagS H32
Version: 04.01.07.00
Page
66