Manual Datafox ZK-Box V4
page 77
date: 16.01.2018 Version: 04.03.06.XX
Overview of the possible parameters for the keywords:
keyword
value / Bit Nr.
description
access
=
or
module
=
function for
1x Bus
RS485
000
010
011
…
081 usw.
The value of the string must follow the format of the "TM" field of the
"Reader" list. He must therefore always include 3 digits.
master
=
1-3
1
2
Id for the RS485 bus ZK, represents the ZK- rs485-bus.
RS485 Bus ID 1
RS485 Bus ID 2…
„
master
“
has to be set together with „
module
“
and so replaces the
function „
access
“
mask
1 / 0
this bit will trigger the buzzer.
2 / 1
this bit will trigger the green LED.
4 / 2
this bit will trigger the red LED.
8 / 3
this bit will trigger the first relay.
16 / 4
this bit will trigger the second relay.
32 / 5
this bit will trigger the third relay.
64 / 6
this bit will trigger the fourth relay.
128 / 7
this bit will trigger the fifth relay.
256 / 8
this bit will trigger the sixth relay.
….
unused. always set to 0
type
0
Off
1
On
2
change (600ms on, 600ms off)
3
3 times on for 500ms
duration
Sekunden / 0 Is a period of time and only at =1 active.
meaning: 0 = always on, 1 - 40 = seconds on.
Hint:
You can also perform multiple actions on the access control in one response. However,
the total length of the response must not
exceed 254 characters
.
!
Attention:
A automated switch between online and offline mode is not possible in http mode