Manual Datafox ZK-Box V4
page 79
date: 16.01.2018 Version: 04.03.06.XX
5.7.8. Funkcionfor access control U&Z (locking cylinders)
5.7.8.1. Design example
The radio locking cylinders are set up and integrated via the standard Datafox access control sys-
tem. The PHG crypt protocol is used. All data is thus securely encrypted.
Functionality:
The electronic locking systems read an RFID chip / card and transmit the read information to Data-
fox access control. The Datafox access control then decides on the basis of the access logic wheth-
er the door is opened or not.
Design example with integrated radio module in the ZK-Box V4.
Entsprechende Reader Tabelle, Beispiel:
ID
ZM / Bus-ID
TM (Busadresse) RefLocation
RefAction
PinGeneral
Description-text
1
1
0
1
0
1
1
0
Reader - RS485 module slot 1 = Bus ID 1
2
1
0
2
0
2
2
0
Reader - RS485 module slot 3 = Bus ID 1
3
1
0
3
0
3
3
0
Reader - RS485 module slot 7 = Bus ID 2
Note:
The transponders are read by the cylinder and the ID is transferred to the ZK-Box. It then
decides whether the ID access is granted and sends a corresponding signal to the cylin-
der.
Note:
Only one radio lock cylinder can be used at a time!
From booking to termination of the radio connection we need approx. 2 seconds for a re-
jection. With an opening approx. 1 second.
If ID cards are held on two or more doors at exactly the same time, the first locking cylin-
der has the connection with the FSM for approx. 2 seconds. If a radio lock cylinder does
not receive a radio connection after 1 second, it performs an offline check. If no ID cards
have been deposited, they will no longer respond to the ID card. The badge is then stored
in the reader and the system no longer reacts to this badge (repeat posting block) until
another badge is available.
ZK-Box V4 or other
V4 Master Terminal
with U&Z radio
module
Transponder ID:
„1656256695“
„5651591001“
access-list - Identification:
1 1656256695 ……
1 5651591001 ……
Range approx. 10 m
Bus Nr.
1
Bus Nr.
2
Bus Nr.
3