Manual Datafox ZK-MasterIV
3.6.1.1 A door without a separate reader
The time recording terminal is access scanner, access master and door-opener at the same time. This
solution should only be used in protected places so that the door opening relay cannot be manipulated.
RS232 / 485
TCP/IP
GSM/GPRS
wLAN
Relay to the door opener
Input for door supervision
3.6.1.2 A door with a separate reader
The ZK-MasterIV is installed in a protected area inside a building and the reader is installed outside.
The terminal is access master and door-opener at the same time. The door opening relay is in the ZK-
MasterIV and thus in the protected area. The access identification captured by the reader is transmitted
to the ZK-MasterIV and analysed by it. If the access is permitted, the door is opened via the relay in the
ZK-MasterIV.
RS232 / 485
TCP/IP
GSM/GPRS
wLAN
Relay to the door opener
Input for door supervision
RS485-wire, 1000 m at most
Reader Type: 106020
Set reader
on RS485
via DIP-switch
This version is used frequently and can be installed easily and economically as shown in the figure above.
Version: 04.01.07.00
Page
62
www.datafox.de