background image

Wagner Meters provides two distinct DataGrabbers

®

 which 

will significantly enhance your documentation of Rapid RH

® 

L6 Smart Sensor readings. DataGrabbers automate the reading 

collection process by interfacing to an L6 sensor, allowing the 

sensor itself to store relative humidity (RH) and temperature 

readings  on  a  periodic  basis  while  you  are  away  from  the 

job site. The DataGrabber with Bluetooth

®

 features a built-

in  wireless  connection  to  your  smart  device. Alternatively,  

the  non-wireless  version  of  the  DataGrabber  uses  the  

Bluetooth

®

-enabled Total  Reader

®

  to  communicate  to  your  

smart device.

The  DataGrabber  with  Bluetooth  easily  inserts  into  an  L6 

sensor  and  directly  connects  with  the  free  DataMaster

 

L6  app  for  automated  collection  of  time  and  date-stamped 

concrete  RH  and  temperature  readings.  The  DataMaster 

L6  app  allows  you  to  configure  the  time  interval  that  the 

DataGrabber with Bluetooth will periodically engage the L6 

Smart Sensor to collect and store readings, keep a running 

clock  of  acclimation  time,  download  the  time  and  date-

stamped readings and much more.

The non-wireless DataGrabber performs the same automated 

and data gathering tasks as the DataGrabber with Bluetooth 

but,  as  mentioned  above,  requires  the  Total  Reader  as  the 

Bluetooth conduit to the DataMaster L6 app. 

By using a DataGrabber to enable an L6 sensor to store up to 

512 RH and temperature readings on a time and date-stamped 

basis, you can achieve a better understanding of the drying 

process  as  well  as  the  dynamics  that  may  be  affecting  the 

concrete drying time. Utilizing RH and temperature readings 

acquired from an L6 sensor with a DataGrabber, data analysis 

and trending is also possible in the DataMaster L6 app.

TABLE OF CONTENTS

DataGrabber

®

 with Bluetooth

®

 

1     

Connect 

          3                                                   

Configuration 

4

Troubleshooting 

6

Removal 

7

Battery 

8

DataGrabber

®

 

9  

Data Collection  

11

Configuration 

12

Removal 

15

Battery 

16

Summary of Contents for RapidRH L6 with Bluetooth

Page 1: ......

Page 2: ...he time interval that the DataGrabber with Bluetooth will periodically engage the L6 Smart Sensor to collect and store readings keep a running clock of acclimation time download the time and date stamped readings and much more The non wireless DataGrabber performs the same automated and data gathering tasks as the DataGrabber with Bluetooth but as mentioned above requires the Total Reader as the B...

Page 3: ...L6 app to set up time intervals for all DataGrabbers with Bluetooth to engage their L6 Smart Sensors to record and store time and date stamped concrete RH and temperature readings for days weeks or months at a time The DataGrabber with Bluetooth can also be accessed through the DataMaster L6 app to set the device name view acclimation time and download sensor data DATAGRABBER Data Logger with Blue...

Page 4: ...sors the unit with the greatest signal strength will appear as the first unit at the top followed by any other DataGrabber units within Bluetooth range Now you can begin to configure your DataGrabber units See Configuration section WAGNER METERS RAPID RH L6 CONFIGURATION Each DataGrabber with Bluetooth can be configured for Device Name Acclimation Time and Log Interval From the Devices screen sele...

Page 5: ...og datalogging Interval This datalogging of RH and temperature readings begins as soon as the DataGrabber with Bluetooth is inserted into the sensor and a new set of readings is logged everytime the Log Interval is met The default and minimum Log Interval is 1 hour Log Duration A calculation of the total number of days that periodic time and date stamped readings will be taken based on the set log...

Page 6: ...head screwdriver 2 Tip the DataGrabber with Bluetooth upside down and tap the bottom of the unit carefully to dislodge the battery into your palm 3 Place the battery within the well positive side up Note the battery text should be visible 4 Insert the battery until it stops Be careful to avoid using excessive force Product Specification Replaceable Battery Life 1 88 years CR 1 3N Storage 512 data ...

Page 7: ...storical data from the L6 Smart Sensor for viewing saving and attaching to reports Click Save to Map to upload the data to your mobile device and display the entire list of time and date stamped RH and temperature data for the L6 Smart Sensor DATAGRABBER Data Logger for Rapid RH L6 RAPID RH L6 WAGNER METERS At the screen displaying the time and date stamped data you are given the option to Store R...

Page 8: ...s and store them for later retrieval using the Total Reader and DataMaster L6 app To configure the DataGrabber first place the Total Reader to make contact with the DataGrabber inserted in a L6 Smart Sensor Once contact is made the DataGrabber then appears on the DataMaster L6 app s Devices screen The screen displays devices in order according to greatest signal power Therefore the DataGrabber sho...

Page 9: ...umentable RH readings After this first measurement other periodic logging continues to occur regardless of the acclimation time period Log Interval Set the desired time number of hours between periodic readings These are the readings that will be grabbed after the initial acclimation time has occurred Write Settings to Device Whenever you change the configuration of the DataGrabber you must click ...

Page 10: ...imilar implement to push through one of the holes on the back to coax the battery out 3 Place the battery within the well positive side up the text should be readable Insert the battery until it stops Be careful to avoid using excessive force 4 Replace the battery compartment cover by guiding the arms of the cover inside the slot and pushing until the cover snaps into place Product Specification B...

Page 11: ...red in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher The information in this document is subject to change without notice Wagner Meters 326 Pine Grove Road Rogue River OR 97537 Worldwide Toll Free 888 266 7756 The RAPID RH L6 DataGrabber is registered under U S Patent 903...

Reviews: