TROUBLESHOOTING
If the DataGrabber with Bluetooth does not show up on the
DataMaster L6 Devices screen.
• Check the connection between the DataGrabber and
the L6 Smart Sensor.
• Ensure that the battery is seated properly or replace the
battery as necessary.
Device Name:
This will be the unique identifier of your
device. The device name can be up to 12 characters long.
NOTE: There will be a default name present in the Device
Name field, but you will likely want to rename it.
Acclimation Time:
The amount of time elapsed (in days)
before the DataGrabber will automatically capture (grab) a
measurement and store in the L6 Smart Sensor’s memory
as the acclimated time measurement of both RH and
temperature. For instance, setting an acclimation time of one
day and then starting, the DataGrabber will wait 24 hours and
“grab” a measurement for storage in the L6 Smart Sensor’s
memory. In most cases, it is highly recommended to use
one day as the acclimation time, given that 24 hours is the
minimum equilibration time specified by the ASTM F2170
standard for getting official, documentable RH readings.
Log Interval:
In addition to the reading captured (grabbed)
when the Acclimation Time has elapsed (see above), an
L6 sensor, through the DataGrabber with Bluetooth, will
begin to capture readings at a certain interval, defined as
the Log (datalogging) Interval. This datalogging of RH and
temperature readings begins as soon as the DataGrabber with
Bluetooth is inserted into the sensor, and a new set of readings
is logged everytime the Log Interval is met. The default and
minimum Log Interval is 1 hour.
Log Duration:
A calculation of the total number of days that
periodic time and date-stamped readings will be taken based
on the set log interval and the L6 Smart Sensor’s maximum
memory storage of 512 data points. Once this limit is reached,
the first stored reading will be overwritten.
Write Settings to Device:
Whenever you change the
configuration of the DataGrabber, you must click the Write
Settings to Device button in order to save the settings.
Default Settings:
If you wish to use the acclimation time and
log interval settings as the default settings for one or more
additional DataGrabbers, click the Save Defaults button. This
saves the settings displayed as your default settings. Then
select another DataGrabber and go to the Settings screen.
Click the Load Defaults button. The default settings will
now be displayed for this device. Be sure to also click the
Write Settings to Device button to save the default settings to
this DataGrabber.
Start and Stop:
After you have saved the desired settings
and are ready to begin data logging, click the Start button to
signal to the DataGrabber to begin the acclimation time.
NOTE: The clock in the DataGrabber will automatically
synchronize to the clock on your mobile device.