DPR-400 User Manual Rev_01 Firmware V-1.0
DPR-400 is a state of the art, color screen,
directional network analyzer and protection relay in
144x144mm standard panel dimensions. Thanks to
its low depth, it saves space in the panel. The device
combines high precision, ease of use and versatility
with a reliable and cost-effective design.
The DPR-400 features dual current measurement
circuits, making it a class 0.5% accuracy analyzer,
and a protection relay capable of measuring 50xIn.
The DPR-400 offers various protection curves to
provide precise protection. Multiple protection curves
can be activated simultaneously.
The DPR-400 displays multiple measurements on its
4.3
” screen. The large display offers ease of use and
provides abundant information.
The device can connect to various Scada systems
easily via USB, isolated RS-485 and Ethernet ports
for remote monitoring.
Modbus and IEC60870-5-103 protocols are
supported through RS-485 port.
Modbus TCP/IP and IEC61850 protocols are
supported over the Ethernet port.
Parameter configuration is done using the buttons on
the front panel or with the free PC software. The
program connects via USB, RS-485 or optionally
over the Internet. Additionally, firmware updates are
performed through the USB port.
Two of the relay outputs of the device have
connection monitoring capability. These outputs
continually check the integrity of the load circuit, and
raise an alarm if the circuit opens.
DPR-400 stores up to 7 oscillographic records in
COMTRADE format in its 1MB internal memory.
The device meets the security, EMC, vibration, and
environmental standards for industrial products.
DPR-400
PROTECTION RELAY
•
4.3” color graphic display, 480x272 pixels
•
Accurate power analyzer (%0.5)
•
4 quadrant energy counters
•
Multiple protection curves
•
Self-test, internal failure monitoring
•
Cold reclosure
•
Configurable digital outputs
•
Configurable relay outputs
•
3 independent adjustment sets
•
Multiple languages
•
All parameters front panel adjustable
•
3 level password protection
•
Free PC program for setup
•
Setup through USB, RS-485, and Ethernet
•
14 x configurable front panel leds
•
Manual & Scada driven closing and opening
•
Firmware upgrade through USB
•
IP65 protection (with optional gasket)
•
Low panel depth, only 55mm
•
Trip counter, service warning
•
IEC Normal, Very, Extreme Inverse
•
UK Long Term Inverse,
•
IEEE Medium, Very, Extreme Inverse
•
US Normal Inverse, Short Time Inverse
ANSI CODE DESCRIPTION
27
Under Voltage (Ph-Ph / Ph-N)
46
Negative Sequence Overcurrent
46BC
Broken Conductor
47
Negative Sequence Over Voltage
49RMS
Thermal Overload
50,51
Overcurrent
50N/51N
Ground Overcurrent
50BF
Breaker Failure
59
Over Voltage (Ph-Ph / Ph-N)
67
Directional Overcurrent
74CT
CT Supervision
79
Reclosure
81O
High Frequency
81U
Under Frequency
CLP
Cold Load Pickup
DESCRIPTION
PROTECTION FUNCTIONS
PROTECTION CURVES
FEATURES