Disabled Menu Options

When SafeConsole mode is enabled, the following menu entries on the K300 are disabled:

• BOOT MODE - Not compatible with SafeConsole
• USER PASSWORD - Previous user passwords are disabled and not compatible with SafeConsole
• SAFECONSOLE - Cannot be disabled once locked. Contact

support@datalocker.com

with

questions

• READ ONLY MODE - Not available within the main menu. Still available in the connection

menu

• ZEROIZE - Admins should use the SafeConsole Factory Reset device action instead

SafeConsole Registration

Once SafeConsole is enabled on the Sentry K300, the device will need to be registered to a
SafeConsole server. This is accomplished by launching a Windows client that is loaded on the K300

when SafeConsole is enabled using the steps above. This Windows client will be mounted to a

separate CD ROM partition. SafeConsole registration can either be done by the End User or by an

Admin.

End User Registration To SafeConsole (Recommended)

1. A SafeConsole Administrator should send out the SafeConsole Endpoint Setup Guide to the

user by entering the user’s email address in the SafeConsole Deployment Wizard found in the
Help section of SafeConsole, under

Deployment Wizard

.

2. The End User will need to unlock the K300 using the admin password and select

CONNECT

from the Connection Menu before plugging their device into their Windows workstation.

3. The CD ROM partition that contains the Unlocker application will then be mounted to the

workstation. Follow the Endpoint Setup Guide to launch the Unlocker Client and enter the

information needed for registration.

4. The Unlocker client will ask the user to enter the K300 password. Enter the K300’s Admin

password. All letters should be entered as capitals.

5. If a valid filesystem (FAT32, exFAT, NTFS) is not found on the K300, such as when registering

after receiving a factory reset through SafeConsole, then the Unlocker client will attempt to
format the K300 with the user selected filesystem. This action may prompt for Window’s admin
permission through a UAC, User Account Control, prompt.

6. Registration is complete once the Control Panel is shown.

© 2018 DataLocker Inc. All rights reserved.

5

Summary of Contents for Sentry K300

Page 1: ...Sentry K300 SafeConsole Deployment Guide DataLocker Inc March 2019 Sentry K300 1...

Page 2: ...ce SafeConsole With The Updater Recommended 3 Option 2 Enable SafeConsole From The Sentry K300 Device Menu 4 Disabled Menu Options 5 SafeConsole Registration 5 End User Registration To SafeConsole Rec...

Page 3: ...tions when it comes to enabling SafeConsole on your K300 device Option 1 Force SafeConsole With The Updater Recommended These steps require administrative privileges on both the Sentry K300 and the Wi...

Page 4: ...for the device is still the default of 1234567 the user will be forced to change the password on the device s 4th unlock after initialization Option 2 Enable SafeConsole From The Sentry K300 Device M...

Page 5: ...SafeConsole Administrator should send out the SafeConsole Endpoint Setup Guide to the user by entering the user s email address in the SafeConsole Deployment Wizard found in the Help section of SafeC...

Page 6: ...ply be re assigned by logging into SafeConsole and navigating to Manage then Drives Click the K300 s serial number to bring up the Device Details window then click Reassign device to another user This...

Page 7: ...will be created after registering to Safe Console When this password is entered to the K300 it will set the original password back to the default 1234567 and force the user to create a new password Us...

Page 8: ...d without launching the Unlocker client This allows the K300 to be unlocked with the keypad and the secure volume will be passed directly to the operating system making the device compatible with any...

Page 9: ...will proceed to the connection menu where CONNECT or READ ONLY MODE can be used to connect the K300 to a host computer Selecting one of these modes will mount the secure volume directly without needi...

Page 10: ...received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules...