Department
TSS L3 LM
Classification
Public
Page 15 18/04/2019
Version
1.0
Date
4/18/2019
Page 15/27
© 2019 Datalogic S.r.l – All Rights Reserved
Configuring the Laser Marker PNIO node on TIA Portal
Once the Laser Marker node has been imported, the user could want to check or change
the settings of this node.
By double clicking on the Laser Marker from the ‘Network View’ of the HW
configuration, the interface will switch to Device View. From here the user is able to:
- assign a new Device Name to the Laser Marker PNIO node;
- choose the size (64, 128 and 254 Bytes) of the Input and/or Output Memory Maps.
A new Device Name can be entered in the Module properties in the section ‘General’-
>’Name’.
Regarding Input and Output Memory sizes, users will be able to check the dafult size of
both areas (254 bytes) from the ‘Device Overview’: if the user wants to change such
memory sizes, he can cancel the default settings from the ‘Device overview’ and then
drag and drop into the Device Overview one of the possible sizes for the Input and
Output Modules.
Both the Device Name and the sizes of the Input and Output memory Maps must
be the same as the ones set inside the Laser Configurator (page 6 of this manual).