Keyboard Interface
Product Reference Guide
227
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the
beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in
10ms increments. A setting of zero specifies no delay.
NOTE
This feature applies ONLY to the Keyboard Wedge interface.
To set the delay:
1.
Determine the desired setting in milliseconds.
2.
Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3.
Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Pro-
gramming Mode.
4.
Scan the bar code: SELECT INTERCHARACTER DELAY SETTING.
5.
Scan the appropriate two digits from the keypad in
, that represent the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code to
abort and not save the entry string. You can then start again at the begin-
ning.
6.
Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this feature.
Table 14. Intercharacter Delay Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
50ms
150ms
600ms
850ms
2
Divide by 10 (and pad with
leading zeroes to yield two-
digits)
05
15
60
85
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT INTERCHARACTER DELAY SETTING
5
Scan Two Characters From
‘0’ and ‘5’
‘1’ and ‘5’
‘6’ and ‘0’
‘8’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Cobalto C05300
Page 12: ...Contents x Cobalto CO5300 Scanner NOTES ...
Page 26: ...Setup 14 Cobalto CO5300 Scanner NOTES ...
Page 44: ...Enter Exit Programming Mode Enable Character 32 Cobalto CO5300 Scanner NOTES ...
Page 228: ...Enter Exit Programming Mode Plessey 216 Cobalto CO5300 Scanner NOTES ...
Page 254: ...References 242 Cobalto CO5300 Scanner NOTES ...
Page 260: ...Technical Specifications 248 Cobalto CO5300 Scanner NOTES ...
Page 274: ...Standard Defaults 262 Cobalto CO5300 Scanner NOTES ...
Page 278: ...Sample Bar Codes 266 Cobalto CO5300 Scanner NOTES ...
Page 280: ...Keypad 268 Cobalto CO5300 Scanner 5 6 7 8 9 A B C ...
Page 281: ...Product Reference Guide 269 D E F ...