Matrix-2000™ Reference Manual
1
CBX100/CBX500 Pinout for Matrix-2000™
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this
pinout when the Matrix-2000™ reader is connected by means of the CBX100/CBX500:
CBX100/500 Terminal Block Connectors
Input Power
Outputs
Vdc
Power Supply Input V
+V
Power Source - Outputs
GND
Power Supply Input Voltage -
-V
Power Reference - Outputs
Earth
Protection Earth Ground
O1+
Output 1 +
O1-
Output 1 -
Inputs
O2+
Output 2 +
+V
Power Source – External Trigger
O2-
Output 2 -
I1A
External Trigger A (polarity insensitive)
O3A
Output 3 +
(CBX500 only – polarity sensitive)
I1B
External Trigger B (polarity insensitive)
O3B
Output 3 -
(CBX500 only – polarity sensitive)
-V
Power Reference – External Trigger
Auxiliary Interface
+V
Power Source – Inputs
TX
Auxiliary Interface TX
I2A
Input 2 A (polarity insensitive)
RX
Auxiliary Interface RX
I2B
Input 2 B (polarity insensitive)
SGND
Auxiliary Interface Reference
-V
Power Reference – Inputs
Shield
Shield
Network Cable Shield
Main Interface
RS232
RS485 Full-Duplex
RS485 Half-Duplex
TX
TX+
RTX+
RTS
TX-
RTX-
RX
*
RX+
CTS
*
RX-
SGND
SGND
SGND
* Do not leave floating, see par. 4.2.2 for connection details.
CAUTION
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
CAUTION
If Matrix-2000™ is connected to a CBX with a BM100 Backup Module, then
the Matrix-2000™ 9-pin Auxiliary port connector cannot be used for
communication (i.e. configuration through VisiSet™). In this case use the
Auxiliary port 9-pin connector inside the CBX.
2