Register Description
Product Reference Guide
25
In order to activate the tag and put it in Idle state the initial date configura-
tion register (INIT_DATE) shall be written with a non-zero value and the tag
shall be reset using the dedicated bit in the INIT_DATE Register at page 15.
In this state the internal clock is active and the tag is waiting for a start log-
ging command (LE in the STATUS register).
Once the LE bit toggle to 1 (start logging) the tag wait for the SAMPLING_DE-
LAY expiration (if the Delay Enable flag is enabled and SAMPLING_DELAY is
different than 0) then it starts the acquisition of the temperature samples.
During the acquisition the tag samples the temperature each BIN_SAMPLE-
TIME[x] seconds (where x is the bin index corresponding to the last tem-
perature sample).
Let now suppose that the temperature has been sampled more than 5 times
in the third bin (Bin 2); in this case an alarm must be generated. The status
of the register will be:
STATUS
= 0x0013
BIN_ALARM flag active and battery status Full
BIN_ALARM
= 0x0004
alarm flag set corresponding to the Bin 2
BIN_COUNTER[2]
= 0x0005
means: 5 samples counted in the Bin 2