DEFAULT VALUES
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled,
USB keyboard speed normal.
DATA FORMAT
: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disabled.
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 5 sec., ack/nack disabled, FIFO enabled, inter-character delay disabled,
serial trigger lock disabled.
DATA FORMAT
: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = CR-LF, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
DATA FORMAT
: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disable.
PEN DEFAULT SETTINGS
interpret operating mode, conversion to code 39 disabled, output level normal,
idle level normal, minimum output pulse 600 µs, overflow medium, inter-block
delay disabled.
CODE SELECTION
Enabled codes
•
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
•
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
•
Standard Code 39
no check digit control, variable length code; 1-99 characters
•
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Code 11, Code 16K, Code 49, RSS Codes
TECHNICAL FEATURES
Dragon
™
D131/D131 LR
Electrical Features
Power Supply
4 to 30 Vdc
Max. Consumption:
@ 4V
@ 5V
@ 30V
Sleep mode
420 mA
310 mA
62 mA
4 mA
Scan Rate
35 ± 5 scans/sec
Reading Indicators
Good Read LED (
green
)
Good Read Spot (
green
),
Beeper
Optical Features
Dragon™ D131
Dragon™ D131 LR
Reading Field
110 cm (43.3 in)
@ 55 mils
225 cm (88.6 in)
@ 55 mils
Max. Resolution
0.076 mm (3 mils)
0.25 mm (10 mils)
PCS (Datalogic Test Chart)
15%
40%
Laser Features
Power (max)
0.9 mW
1.4 mW
Scan Angle
42°
23°
Laser Safety Class
Class 2 EN 60825-1/CDRH
Environmental Features
Working Temperature
-30
°
C to + 50
°
C / -22° to +122 °F
Storage Temperature
-30
°
C to + 70
°
C / -22° to +158 °F
Humidity 90%
non
condensing
Drop Resistance
IEC 68-2-32 Test ED 2 m
Protection Class
IP64
Mechanical Features
Weight (without cable)
about 295 g (10.4 oz)
Cable Length
2 m (6 ft 6 in)
RESTORE DEFAULT
RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the Dragon™ D131/M131 Reference Manual, part
number
90ACC1929
, or to the Datalogic Aladdin™ Configuration program, both
downloadable from the website.
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Hand
Held
Ì$+UA01$-.Î
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation software, which can be downloaded from the
web site http://www.scanning.datalogic.com.
PEN EMULATION INTERFACE SELECTION
PEN
Ì$+CP6$-BÎ
RS232 INTERFACE SELECTION
RS232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL
Mode
Ì$+CM0$-ÃÎ
WEDGE INTERFACE SELECTION
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
PC
Notebook
Ì$+CP505$-ÈÎ
PC Notebook - ALT mode
Ì$+CP508$-2Î
IBM AT - ALT mode
Ì$+CP507$-+Î
Many other interfaces are supported and can be selected from the
Dragon™ D131/M131 Reference Manual available online at
http://www.scanning.datalogic.com. Other supported interfaces:
USB
: USB-IBM-Table Top; USB-KBD-APPLE
WEDGE
: IBM XT; IBM SURE1; IBM Terminal 3153; IBM Terminals 31xx, 32xx,
34xx, 37xx; Wyse Terminals ANSI – PC –ASCII – VT220 style Keyboards; Digital
Terminal VT2xx/VT3xx/VT4xx; APPLE ADB Bus
KEYBOARD NATIONALITY
USB-KBD and Wedge users should select one of the following wedge keyboard
nationality codes according to the keyboard.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA
(Default)
Ì$+FJ0$-|Î
The following Keyboard Nationality selections are only valid for IBM AT compatible
PCs:
Japanese
Ì$+FJ8$-=Î
Russian
(Latin)
Ì$+FJ9$-BÎ
Russian (Cyrillic)
Ì$+FJA$-jÎ
Hungarian
Ì$+FJB$-oÎ
Slovenian, Croatian, Serbian (Latin)
Ì$+FJC$-tÎ
Romanian
Ì$+FJD$-yÎ
Czech Republic
Ì$+FJE$-~Î
USING DRAGON™ D131/D131 LR READERS
Dragon™ D131 readers automatically scan barcodes
at a distance.
Simply aim
and pull the trigger. Code scanning is performed along the scan line emitted from
the reading window. This line must cross the entire code. The best reading angles
are indicated in the figure below.
AIMING SYSTEM
Dragon™ D131 and Dragon™ D131 LR provides an aiming system. If enabled, a
partial trigger press produces a red spot, which should be aimed over the code
center to get the best reading performance (see figure above,
c
). By completely
pressing the trigger the scan line appears to start code scanning
d
.
After setting up the reader, you can enable or disable the aiming system by
reading the codes below:
Disable Aiming System (Default)
Ì$+Bj0$-"Î
Enable Aiming System
Ì$+Bj1$-'Î
DATA FORMAT TERMINATORS
For your convenience, some common Terminators are given below. For other
Header/Terminator selections, Data Format and Advanced Data Format
parameters, see the Dragon™ D131/M131 Reference Manual.
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ
OPERATING TEST
Read the TEST code below.
Code 128
t
e
s
t