background image

 

 

DS1500 QUICK GUIDE

 

2  

 

Power Supply: 

 

-  This product is intended to be installed by Qualified Personnel only. 

- All 

Models: 

This accessory device is intended to be supplied by a UL Listed or CSA Certified Power Unit with «Class 2» or 
LPS power source, which supplies power directly to the scanner via the 

15

-pin connector. 

 
The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser 
product according to CDRH regulations. 
 
Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to 
hazardous laser light. 
 
There is a safety device, which allows the laser to be switched on only if the motor is rotating above the threshold 
for its correct scanning speed. 
 
The laser beam can be switched off through a software command (see also the WinHost Help On Line). 
 

 

Warning and Device Class Label 

 

 
The laser diode used in this device is classified as a class 3B laser product according to EN 60825-1 regulations 
and as a Class IIIb laser product according to CDRH regulations. As it is not possible to apply a classification 
label on the laser diode used in this device, the following label is reproduced below. 
 

 

LASER LIGHT 

AVOID EXPOSURE TO BEAM 
CLASS 3B LASER PRODUCT 

MAX. OUTPUT RADIATION  35 mW 

EMITTED WAVE LENGTH  630~680 nm 

TO EN 60825-1 (2001) 

 

Laser Diode Class Label 

 
Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (35 
mW at 630 to 680 nm). 
 
 

 

Summary of Contents for DS1500-1100

Page 1: ... pin D sub Male Connector 11 Figure A For further details on product installation see the complete Reference Manual DS1500 can be configured through the WinHost Windows based software program available on the installation CD ROM part number 93ACC1771 For configuration it is necessary to create a cable connecting the scanner to the PC as indicated in the How To Build A Simple Interface Test Cable s...

Page 2: ...laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed The laser beam can be switched off through a software command see also the WinHost Help On Line Warning and Device Class Label The laser diode used in this device is classified as a class 3B laser product according to EN 60825 1 regulations and as a Class IIIb laser product according to CDRH re...

Page 3: ... voltage 5 Vdc 5 Power consumption max 2 W Serial Interfaces Main RS232 RS485 Full duplex Half duplex Auxiliary RS232 Baud Rates 150 to 115200 Inputs External Trigger Voltage max 40 Vdc Outputs OUT1 OUT2 VCE max 40 Vdc Collector current max 20 mA continuous VCE saturation 0 3V at 6 mA max Power dissipation max 100 mW at 45 C Ambient temp OPTICAL FEATURES Light source Semiconductor laser diode Wave...

Page 4: ... ACB Advanced Code Builder Motor Off Parameter Storage Non volatile internal EEPROM ENVIRONMENTAL FEATURES Operating temperature Note 2 0 to 45 C 32 to 113 F Storage temperature 20 to 70 C 4 to 158 F Humidity max 90 non condensing Vibration resistance 14 mm 2 to 10 Hz EN 60068 2 6 2 hours on each axis 1 5 mm 13 to 55 Hz 2 g 70 to 200 Hz Shock resistance EN 60068 2 27 3 shocks on each axis 30 g 11 ...

Page 5: ...onnected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 15 pin male high density D sub connector pinout Pin Name Function 1 VS Power supply input voltage 5 GND Power supply input voltage 8 PE Protective Earth Ground 13 SHIELD Cable Shield 9 EXT TRIG External Trigger 7 OUT...

Page 6: ... 30 31 3 1 23 3 1 0 12 N 2 4 6 0 18 22 0 87 40 1 57 1 0 04 mm inch MØ2 3 2 0 13 3 2 0 13 11 0 43 6 0 24 62 2 44 20 0 79 25 0 98 1 5 0 06 inch mm 7 1 0 28 31 8 1 25 31 8 1 25 25 1 0 99 12 0 47 The quote refers to the scan line DS1500 Overall Dimensions Mounting Bracket Overall Dimensions Skew Pitch ...

Page 7: ... USER INTERFACE Vext 40 Vdc max 20 mA max DS1500 7 14 5 GND Ground VCE max 40 Vdc I max 20 mA continuous Connectivity RS232 Point to point Layout RS485 Point to point Layout Terminal Host DS1500 3 1 2 Host DS1500 2 1 c Main Serial Interface RS232 c Main Serial Interface RS485 Full Duplex dAuxiliary Serial Interface Local Echo d External Trigger for On Line Mode eExternal Trigger for On Line Mode R...

Page 8: ...ding Diagrams DS1500 1100 2 1 0 1 5 4 3 2 3 4 5 in 0 1 3 2 10 6 in 4 5 7 8 9 0 20 40 60 80 100 120 140 160 180 200 220 240 260 mm 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 0 50 mm 20 mils 0 20 mm 8 mils 0 15 mm 6 mils 0 30 mm 12 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Motor Control S...

Page 9: ...60 50 40 30 20 10 0 10 20 30 40 50 60 mm 0 20 mm 8 mils 0 12 mm 5 mils 0 10 mm 4 mils 0 5 3 5 4 5 1 5 2 5 0 15 mm 6 mils NOTE 0 0 is the center of the laser beam output window CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Motor Control Speed_3 800 scans s Parameter selectable in Winhost ...

Page 10: ... 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagrams show a simple test cable including power external push button trigger and PC RS232 COM port connections PC 15 pin D sub HD female 4 10 SGND RXAUX TXAUX 6 DS1500 5 1 GND VS 9 pin D sub female GND TX RX 2 3 5 Power Supply VS 5 Vdc Power GND Trigger EXT TRIG 9 Test Cable for DS...

Page 11: ......

Page 12: ...lectromagnetic compatibility and product safety Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electro...

Reviews: