DS1500
3
3.4 READING
DIAGRAMS
DS1500-1100
2
1
0
1
5
4
3
2
3
4
5
(in)
0 1
3
2 10
6
(in)
4
5
7
8
9
0 20 40 60 80 100 120 140 160 180 200 220 240 260
(mm)
120
100
80
60
40
20
0
20
40
60
80
100
120
(mm)
0.50 mm
(20 mils)
0.20 mm
(8 mils)
0.15 mm
(6 mils)
0.30 mm
(12 mils)
NOTE:
(0,0) is the center of the laser beam output window.
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
"Pitch" angle = 0
°
"Skew" angle = 15
°
"Tilt" angle = 0
°
*Motor Control = Speed_3 (800 scans/s) for 0.15mm codes, Speed_4 (1200 scans/s) for
0.20mm codes and greater
•
Parameter selectable in Winhost
34