DATALOGIC
DS2200
Installation - 7
120 Ohm
max. 1200 m.
RTX485 -
Three wires + shield
MULTIPLEXER
# 1
DS2200
RTX485-
SGND
# 0
DS2200
DS2200
# x
(up to 31)
120 Ohm
max. 2 m.
7
4
5
RS485 REF
7
4
5
7
4
5
SHIELD
Figure 2.6 - DS2200 Multidrop connection to a Multiplexer
2.3.3 Auxiliary Interface - RS232
The auxiliary serial interface is used exclusively for RS232 point-to-point
connections. It is also used for configuring the DS2200.
The parameters relative to the auxiliary interface (baud rate, data bits, etc.)
can be defined using the Winhost utility program or "Host Mode
Programming" installed from the diskette.
The following pins of the 25-pin connector are used to connect the RS232
auxiliary interface:
Pin
Name
Function
3
RXAUX
RS232 received data
2
TXAUX
RS232 transmitted data
7
SGND
Signal Ground