background image

 

 

DS2400A QUICK GUIDE

 

DS2400A 

General View: 

Laser Safety: 

The scanner is classified as a Class 2 laser 
product according to EN 60825-1 regulations 
and as a Class II laser product according to 
CDRH regulations. 
 
Disconnect the power supply when opening the 
device during maintenance or installation to 
avoid exposure to hazardous laser light. 
 
There is a safety device which allows the laser to 
be switched on only if the motor is rotating above 
the threshold for its correct scanning speed. 
 
The motor and laser beam can be switched off 
through a software command (see also the 
WinHost Help On Line). 
 

 

CAUTION-CLASS 3B LASER LIGHT 

WHEN OPEN AVOID EXPOSURE TO BEAM

This product conforms to the applicable
requirements of 21CFR1040 at the date
of manufacture. 

LASER LIGHT 

DO NOT STARE INTO BEAM 

CLASS 2 LASER PRODUCT 

MAX. OUTPUT RADIATION  1 mW 

EMITTED WAVE LENGTH  630~680 nm 

TO EN 60825-1:2001 

R

C

US

218441

N2468

 

 Figure 

 

Power On / Data TX LED

External Trigger LED 

Good Read LED 

Laser On LED 

Warning and Device Class Label

Laser Beam Output Window 

Accessory Mounting Holes

Mounting Holes 

 

For further details on product installation, see the 
complete Reference Manual on the installation CD-ROM. 

DS2400A can be configured through the WinHost 
Windows-based software program available on the 
installation CD-ROM. 

For configuration it is necessary to create a cable 
connecting the scanner to the PC as indicated in the 
“How To Build A Simple Interface Test Cable” section of 
this guide, otherwise you can use the C-Box 100. 

 

Power Supply: 

-  This product is intended to be installed by Qualified 

Personnel only. 

- All 

Models: 

  This accessory device is intended to be supplied by a UL 

Listed or CSA Certified Power Unit with «Class 2» or LPS 
power source which supplies power directly to the 
scanner via the 25-pin connector. 

 

 

 

Warning and Device Class Labels

 

The laser diode used in this device is classified 
as a class 3B laser product according to EN 
60825-1 regulations and as a Class IIIb laser 
product according to CDRH regulations. As it is 
not possible to apply a classification label on 
the laser diode used in this device, the following 
label is reproduced below. 
 

 

LASER LIGHT 

AVOID EXPOSURE TO BEAM 
CLASS 3B LASER PRODUCT 

MAX. OUTPUT RADIATION  7 mW 

EMITTED WAVE LENGTH  630~680 nm 

TO EN 60825-1 (2001) 

 

Laser Diode Class Label 

 
Any violation of the optic parts in particular can 
cause radiation up to the maximum level of the 
laser diode (7 mW at 630 to 680 nm). 

WEEE Compliance: 

 

 

7

6

1

2

3

4

Summary of Contents for DS2400A

Page 1: ...ee the complete Reference Manual on the installation CD ROM DS2400A can be configured through the WinHost Windows based software program available on the installation CD ROM For configuration it is necessary to create a cable connecting the scanner to the PC as indicated in the How To Build A Simple Interface Test Cable section of this guide otherwise you can use the C Box 100 Power Supply This pr...

Page 2: ...rrent Consumption 25 mA Operating Modes On Line Automatic max Serial On Line Test Outputs Configuration Modes Through menus using OUT1 OUT2 optocoupled WinHost utility Host Mode commands from VCE max 40 Vdc one of the serial ports Collector Current 40 mA continuous Code Selection Up to six different codes max 130 mA pulsed during one reading phase VCE Saturation 1V at 10 mA max Decoding Safety Can...

Page 3: ... and bring system wiring to it see the relative C Box Installation Manual CAUTION Do not connect GND and SGND to different external ground references GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 25 pin D sub female connector pinout ...

Page 4: ...wer MEP 543 Connector DS2400A 18 19 5V VS 9 25 GND EXT TRIG EXT TRIG 4 3 2 1 brown white blue Input NPN command using MEP 543 Photocell OUTPUT EXTERNAL TRIGGER DS2400A Signal 18 19 5V VS 9 25 GND Ground V EXT TRIG EXT TRIG Input NPN command using DS2400A power USER INTERFACE 8 11 12 22 OUT REF DS2400A Vext 40 Vdc max C E Output open collector connections INPUT PNP 18 19 5V DS2400A EXTERNAL TRIGGER...

Page 5: ...al Interface RS232 c Main Serial Interface RS485 Half Duplex dAuxiliary Serial Interface RS232 dAuxiliary Serial Interface Local Echo RS232 eExternal Trigger for On Line Mode eExternal Trigger for On Line Mode RS232 Master slave layout RS485 Master slave layout c Main Serial Interface Slaves RS232 only c Auxiliary Serial Interface RS232 dAuxiliary Serial Interface RS232 d Main Serial Interface RS4...

Page 6: ...35 cm 3 4 in 1 2 0 1 2 3 4 2 6 4 12 8 10 14 in 0 35 mm 14 mils 0 20 mm 8 mils 0 25 mm 10 mils DS2400A 1200 Medium Reading Range CONDITIONS Optic Version Linear Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 10 Tilt angle 0 Code Resolution High for 0 25 mm 10 mils codes Std for 0 35 mm 14 mils codes and greater Code Reading Condition Standard Scanning Speed Speed_3 800 scans s Pa...

Page 7: ... Interface The following table contains the pinout for standard RS232 PC Host interface For other user interface types please refer to their own manual RS232 PC side connections 5 9 6 1 9 pin male connector 13 25 14 1 25 pin male connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple...

Page 8: ...compatibility and product safety Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las...

Reviews: