ALTERNATIVE CONNECTIONS FOR SERIAL MODELS
135
A
ID-NET NETWORK TERMINATION
The network must be properly terminated by a 120 Ohm resistor at the first and last reader of
the network.
INPUTS
There are two optocoupled polarity insensitive inputs available on the 25-pin D-sub
connector of the reader: Input 1 (External Trigger) and Input 2, a generic input.
The electrical features of both inputs are:
V
AB
Max.
I
IN
Max
.
30 V
12 mA
The relative pins on the 25-pin D-sub connector are:
Pin
Name
Function
9
Vdc
Power Supply input v
18
I1A
External Trigger A (polarity insensitive)
19
I1B
External Trigger B (polarity insensitive)
6
I2A
Input 2 A (polarity insensitive)
10
I2B
Input 2 B (polarity insensitive)
7
GND
Power Supply input voltage -
Vdc
GND
I1A
I1B
Photocell PNP MEP-593
SCANNER
18
19
7
(brown) +10-30 Vdc
(black) NO
(blue) 0 V
V
CC
~
~
+
-
9
Figure 77
– MEP-593 PNP Photocell Connections Using Scanner Power