DS5100 REFERENCE MANUAL
32
2
Reading Results:
A A A A
X X X X X X X X X X X
Y Y C o
d
e
s
A = reading result
– Good (Good Read), Part (Partial Read), Mult (Multiple Read)
X = code content
Y = number of codes read
G o
o
d
X X X X X X X X X X X
Y Y
D G T
D
W W W
S S S
X = code content
Y = number of digits in the code
DGT = "digits"
D = code direction
– F=forward, R=reverse, U=unknown
Linear Reading (only if the Quality Counters parameter is enabled)
W = number of scans on the code
S = Quality Counters value (max 100)
Code Reconstruction
W = number of scans on the code (max 255)
S = number of decodes (max 255), on the digit in the code which was decoded the least
number of times
Network Diagnostic Messages (Master only):
The display alternates between message 1 and 2.
0
N e
t
w o
r
k
1
5
M S S S S S S S S S S S S S S S
1
6
N e
t
w o
r
k
3
1
S S S S S S S S S S S S S S S S
M = Master diagnostic condition; S = Slave diagnostic condition:
*
= scanner OK
-
=scanner not detected at startup
?
=scanner detected at startup but not responding to diagnostic polling
!
= scanner diagnostic error
Message 1
Message 2
Summary of Contents for DS5100-X200
Page 1: ......
Page 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection ...
Page 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions ...
Page 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks ...
Page 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it ...
Page 163: ...147 X X PRESS Human Machine Interface 23 ...
Page 164: ......