DS6400 REFERENCE MANUAL
54
5
5 LONWORKS CONNECTIONS
CAUTION
Do not connect an RS232 port to the 9-pin Lonworks Connector. This may
damage your Laptop PC
.
The local network used by DS6400 exploits a Lonworks standard communication system
requiring only two wires (polarity insensitive) to enable a connection. The connector also
provides a positive and a negative supplying wire. In this way, all the slave readers can be
powered by the master through the Datalogic standard cables.
When working in applications requiring enhanced synchronization capabilities, the DS6400
master reader (output) transmits two system signals named Sys_I/O and Sys_Enc_I/O to the
slave readers (input). For example, when working with applications requiring an encoder the
signal is received by the master and directly transmitted to the slaves through the cable.
The internal circuits generating the system signals are externally supplied by means of the
VS_I/O and REF_I/O pins and are isolated from the reader supply voltage.
The use of these system circuits is not required in all the operating modes. Anyway, for
correct system functioning it is suggested to use Datalogic cables and accessories and follow
the description of the typical layouts (see chapter 7 for details).
5
1
9
6
Female (all models)
1
5
6
9
Male (Master/Slave model)
Figure 70 - 9-pin Local Lonworks Connectors
The following pinout is valid for both connectors.
DS6400 9-pin Lonworks Connector Pinout
Pin
Name
Function
1
CHASSIS
Cable shield internally connected by capacitor to chassis
9
VS
supply voltage 15 to 30 vdc (positive pin)
2
GND
supply voltage (negative pin)
6
VS_I/O
Supply voltage of I/O circuit
3
Ref_I/O
Reference voltage of I/O circuit
4
SYS_ENC_I/O System signal
5
SYS_I/O
System signal
7
LON A
Lonworks line (polarity insensitive)
8
LON B
Lonworks line (polarity insensitive)
Summary of Contents for DS6400