INSTALLATION
15
2
2.3.1 Main/Aux. Serial Interface and I/O Connector
The DS6500 master/slave model is equipped with a 25-pin male D-sub connector for
connection to the host computer, power supply and input/output signals.
The DS6500 fieldbus models (Ethernet, DeviceNet, Profibus) adopt a 26-pin male connector
instead of the 25-pin one.
The details of the connector pins are indicated in the following table:
10
19
1
18
9
26
14
1
25
13
Figure 23 - 26-pin Connector
Figure 24 - 25-pin Connector
DS6500 25-pin/26-pin D-sub connector pinout
Pin Name
Function
1
Shield
Cable shield - internally connected by capacitor to the chassis
20
RXAUX
Receive data of auxiliary RS232 (referred to GND)
21
TXAUX
Transmit data of auxiliary RS232 (referred to GND)
8
OUT 1+
Configurable digital output 1 - positive pin
22
OUT 1-
Configurable digital output 1 - negative pin
11
OUT 2+
Configurable digital output 2 - positive pin
12
OUT 2-
Configurable digital output 2 - negative pin
16
OUT 3A
Configurable digital output 3 - polarity insensitive
17
OUT 3B
Configurable digital output 3 - polarity insensitive
18
EXT_TRIG A External trigger (polarity insensitive)
19
EXT_TRIG B External trigger (polarity insensitive)
6
IN 2A
Input signal 2 (polarity insensitive)
10
IN 2B
Input signal 2 (polarity insensitive)
14
IN 3A
Input signal 3 (polarity insensitive)
15
IN 4A
Input signal 4 (polarity insensitive)
24
IN_REF
Common reference of IN3 and IN4 (polarity insensitive)
9,13
VS
Supply voltage - positive pin
23,25,26* GND
Supply voltage - negative pin
Main Interface Connector Pinout
Pin
RS232
RS485
Full Duplex
RS485
Half Duplex
20 mA C.L.
(INT-60 Only)
2
TX
TX485 +
CLOUT +
3
RX
RX485 +
CLIN +
4
RTS
TX485 -
RTX485 -
CLOUT -
5
CTS
RX485 -
CLIN -
7 GND_ISO GND_ISO GND_ISO GND**
* Pin 26 is only available for fieldbus models (Ethernet, DeviceNet, Profibus).
** For 20 mA C.L. connections, GND is the same of the scanner power supply.