Integration Guide
17
Chapter 5
Quality and Reliability
Test ID Test
Description
1
Shock
Dynamic Shock:
2000 G ± 5% applied via any mounting surface at -30º C and 70º C for a
period of 0.85 ± 0.05 msec.
2500 G ± 5% applied via any mounting surface at 23º C for a period of 0.85 ±
0.05 msec
Vibration:
20 to 80 Hz Ramp up at 0.04 G
2
/Hz at 3 dB/octave
80 to 350 Hz 0.4 G
2
/Hz
350 Hz to 2 kHz Ramp down at 0.04 G
2
/Hz at 3 dB/octave
2
Environmental
Storage Temperature: -40° C to +70° C
Operating Temperature: -15° C to +55° C
Humidity (non-condensing)
≤
95%
4
ESD
The Scan Engine must be shielded from ESD strikes up to ±15KV with the
enclosure.
To date, testing on the Imager Module has been performed at level of 2,5KV
on the connector. The module was tested inside another host product up to
4Kv direct and 8KV air.
5
MTBF
An MTBF calculation has been completed and is shown in Appendix A