DX6400
4
4.4 READING CONDITIONS
•
ANSI Grade B minimum
•
600 scans/sec per leg
The following tables describe the requirements for standard applications.
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
14 16 18 20 22 24
0.50
18 19 21 23 25 27
0.60
21 22 24 26 28 30
2/5 Inteleaved
Code Resolution
(mm)
1.00
34 35 36 37 39 41
Table 1
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
12 13 15 17 19 21
0.50
15 16 17 19 21 24
0.60
18 19 20 21 23 26
Code 39
Code Resolution
(mm)
1.00
28 29 30 31 32 34
Table 2
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
10 12 14 16 18 20
0.50
12 13 16 18 20 22
0.60
14 15 17 19 21 24
Code 128 – Ean 128
Code Resolution
(mm)
1.00
22 23 24 26 28 30
Table 3
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
16 18 20 22 24 26
0.50
20 22 24 26 28 30
0.60
23 25 27 29 31 34
Codabar
Code Resolution
(mm)
1.00
36 38 40 42 44 47
Table 4
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
11 12 13 15 17 19
0.50
13 14 15 16 18 20
0.60
15 16 17 18 19 22
EAN 8-13, UPC-A
Code Resolution
(mm)
1.00
24 25 26 27 28 29
Table 5