Barcode Settings Table
Reference Manual
71
EAN-13, EAN-8, UPC-A, UPC-E, All EAN-UPC, Aztec, DataMatrix. Maxicode
Decoding Safety
Enter a number from 1 to 100 (1 = control disabled) in the field provided. It verifies
that an N number of decodes are performed with the same result before code
reading is accepted as valid. Only available when Reading Mode is Linear.
Decoding Severity
Enter a number from 1 to 5 (1 = lowest severity level and 5= highest severity level).
During decoding poorly printed or damaged codes can be discarded because they
do not match the expected code. The Decoding Severity defines a ratio between the
actual and the expected code image. The lower the ratio, the higher the difference
between images. Setting a low value increases the possibility for decoding errors.
Match Direction Rule
Select Disable, Forward, or Reverse from the drop-down list. This parameter
defines the direction, according to which a code can be transmitted. The direction
refers to the code direction with respect to the scan line, in particular: Forward =
the code start character precedes the stop character in the scan line (Start Ch +
Code + Stop Ch); Reverse = the code stop character precedes the start character in
the scan line (Stop Ch + Code + Start Ch)
Disable: All codes are transmitted no matter what the direction is
Forward: All codes having a forward direction are transmitted
Reverse: All codes having a reverse direction are transmitted
Codabar
Decoding Safety
Enter a number from 1 to 100 (1 = control disabled) in the field provided. It verifies
that an N number of decodes are performed with the same result before code
reading is accepted as valid. Only available when Reading Mode is Linear.
Decoding Severity
Enter a number from 1 to 5 (1 = lowest severity level and 5= highest severity level).
During decoding poorly printed or damaged codes can be discarded because they
do not match the expected code. The Decoding Severity defines a ratio between the
actual and the expected code image. The lower the ratio, the higher the difference
between images. Setting a low value increases the possibility for decoding errors.
Contact Datalogic Technical Support before modifying the Decoding Safey or Decod-
ing Severity parameters.
Contact Datalogic Technical Support before modifying the Decoding Safey or Decod-
ing Severity parameters.
Summary of Contents for DX8210
Page 1: ...DX8210 Reference Manual Omnidirectional Barcode Scanner ...
Page 31: ...Installation Reference Manual 19 Small Side Mounted L Bracket Options ...
Page 45: ...Tachometer Wiring to CBX510 Reference Manual 33 ...
Page 47: ...Tachometer Wiring to CBX510 Reference Manual 35 ...
Page 49: ...Digital Output Configuration to CBX510 Reference Manual 37 Unpowered Outputs Powered Outputs ...
Page 268: ...Barcode Scanning Features 256 DX8210 Barcode Scanner DX8210 2100 0 25 mm 10mil ...
Page 269: ...Reading Diagrams Reference Manual 257 DX8210 2100 0 30 mm 12mil ...
Page 270: ...Barcode Scanning Features 258 DX8210 Barcode Scanner DX8210 2100 0 38 mm 15mil ...
Page 271: ...Reading Diagrams Reference Manual 259 DX8210 2100 0 50 mm 20 mil ...
Page 272: ...Barcode Scanning Features 260 DX8210 Barcode Scanner DX8210 4100 0 38 mm 15 mil ...
Page 273: ...Reading Diagrams Reference Manual 261 DX8210 4100 0 50 mm 20 mil ...
Page 274: ...Barcode Scanning Features 262 DX8210 Barcode Scanner DX8210 4200 0 25 mm 10 mil ...
Page 275: ...Reading Diagrams Reference Manual 263 DX8210 4200 0 30 mm 12 mil ...
Page 297: ...Reference Manual 285 ...
Page 298: ......
Page 299: ......