CONNECTIONS

 

 

 

USB Client Connection

 

 
Connect the Single Slot Dock to the host by means of a Micro-B USB 
cord, such as Datalogic 94A051968 cable. 
 
Once the host has been turned on, insert the Elf or the Falcon X3 into the 
cradle. 
 

 

Figure 7 - USB Connection 

 
Key: 

A) Host 

computer 

B) 

94A051968 Micro-B to Std-A  USB straight cable 

C) 

94A151124 Elf Single Slot Dock/ 94A151125 Falcon X3 Single Slot 

Dock 

D) 

94ACC1381 Power Adapter 

 
 

Connection to USB peripherals

 

 
Connect the Single Slot Dock to the peripheral by means of a Micro-A 
USB cord, or use a Micro-A to Std-A receptacle USB adapter such as 
Datalogic 94A051969 (together with a standard USB cable if needed). 
 

 

Figure 8 - USB Peripheral Connection 

Key: 

A) 

USB Peripheral (memory) 

B) 

Standard A to Micro A USB Cable 

C) 

94A051969 Micro-A to Std-A receptacle USB adapter 

D) Single 

Slot 

Dock 

E) 94ACC1381 

Power 

Adapter 

 
 

RS232 Connection

 

 
Connect the Single Slot Dock to the host by means of a standard null 
modem cable such as Datalogic 94A051020 CAB-427 for 9-pin 
connections.  
 
Once the host has been turned on, insert the Elf or the Falcon X3 into the 
cradle. 
 

 

Figure 9 – RS232 Connection 

Key: 

A) Host 

computer 

B) 

94A051020 9-pin serial cable 

C) Single 

Slot 

Dock 

D) 94ACC1381 

Power 

Adapter 

 

 

Communication Module Extensions 

 

To install a communication module, remove the label covering the 
communication module connector on the bottom of the cradle, as 
shown in the figure below: 
 

 

Figure 10 

 

The communication modules available are the following: 
 

 

822000950 Single Slot Dock Ethernet Module  

 

94ACC1372 Single Slot Dock Modem Module.  

 

 
 

TECHNICAL FEATURES 

 

Electrical Features 

Power supply * 

5  VDC ± 5% @ 3A 

Consumption 

Max 3 A with mobile computer inserted 

Spare slot charge time 

 

 

Elf Std Battery 

4h 20 

 

Falcon X3/ Elf 
High Cap 
Battery 

6h 30 (with mobile computer inserted) 
5h (when mobile computer is not inserted) 

Communication Features 

Interface 

RS232, USB 1.1 version 

Baud Rate 

RS232 = 9600 - 115200 

Physical Features 

Dimensions 

110 x 140 x 72 mm 
4,3 x 5,5 x 2,8 in 

Weight (without 
connection cables) 

185 g / 6,5 oz 

Indicators 

Green power-on LED 
Bicolored battery charge status LED 

Environmental Features 

Working temperature** 

0° to +50°C / 32° to 122°F ** 

Storage temperature 

-20° to +70°C / -4° to 158°F 

Humidity 

95% without condensation 

Electrostatic discharge 
EN 61000-4-2 

4 KV contact / 8 KV air 

Use only DL approved power adapters. 

** 

When inserted in the spare slot, standard batteries must be charged at 
a temperature ranging from 0° to 40 °C. 
When inserted in the spare slot, s, high batteries must be charged at a 
temperature ranging from 0° to 35 °C. 
At higher values the charging may slow down.  

 
 

FCC COMPLIANCE

 

 
This equipment has been tested and found to comply with the limits for a 
Class A digital device, pursuant to part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely 
to cause harmful interference in which case the user will be required to 
correct the interference at his own expense. 
Modifications or changes to this equipment without the expressed written 
approval of Datalogic could void the authority to use the equipment. 
This device complies with PART 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference which may cause undesired operation. 

 

 

A

B

Reviews: