Programming Parameters
F-4
Falcon
®
4400 Series with Windows
®
CE
Send Start/
Stop
Instructs the decoder to transmit
the decoded start and stop charac-
ters of Codabar labels. The start
and stop characters will both be
translated as A, B, C, or D.
0
3
0
5
On or
Off
Off
On
Off
9
9
Convert to
CLSI
Restricts the Codabar decoder to
only read labels that conforms to
specifications. Label length
must be 14, and the data is split
into fields of 1, 4, 5, and 4 charac-
ters separated by spaces.
0
3
0
6
On or
Off
Off
Off
Off
9
Allow Wide
Interchar-
acter Gaps
Allows wide gaps to appear
between characters in a label.
0
3
0
7
On or
Off
Off
On
On
9
Minimum
Label
Length
Set the minimum label length to be
less than or equal to maximum
label length.
0
3
2
0
01 - 50
01
01
04
9
9
Maximum
Label
Length
This feature specifies the maximum
allowable length of a Codabar label.
The length includes check and data
characters. Maximum Label Length
should be greater than or equal to
Minimum Label Length.
0
3
2
1
01 - 50
01
50
20
9
9
Read Veri-
fication
Sets the number of times a label
must be read before it is transmit-
ted.
0
3
2
2
01 - 04
01
02
01
9
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults
Scanner Type
Min
Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er
Summary of Contents for Falcon 4410
Page 8: ...Contents vi Falcon 4400 Series with Windows CE NOTES ...
Page 100: ...Accessories A 12 Falcon 4400 Series with Windows CE NOTES ...
Page 116: ...Falcon Desktop Utility for Windows CE B 16 Falcon 4400 Series with Windows CE NOTES ...
Page 172: ...Programming Parameters F 46 Falcon 4400 Series with Windows CE NOTES ...
Page 238: ...Index Falcon 4400 Series with Windows CE NOTES ...
Page 239: ......