background image

822001750 

09/14

www.datalogic.com

© 2014 Datalogic ADC S.r.l.   All rights reserved. 
Datalogic and the Datalogic logo are registered 
trademarks of Datalogic S.p.A. In many countries, 
including the U.S.A. and the E.U.

User’s Manual

Mobile Computer

 

Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561

Datalogic ADC S.r.l.

Summary of Contents for falcon x3+

Page 1: ...alogic and the Datalogic logo are registered trademarks of Datalogic S p A In many countries including the U S A and the E U User s Manual Mobile Computer Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Telephone 39 051 3147011 Fax 39 051 3147561 Datalogic ADC S r l ...

Page 2: ...Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic page Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and ...

Page 3: ...S 19 3 1 USB Connection 19 3 2 Connection to USB Peripherals 21 3 3 RS232 Connection 23 3 4 WLAN Connection 24 3 5 WPAN Connections 26 3 6 Wireless and Radio Frequencies Warnings 27 4 USE AND FUNCTIONING 29 4 1 Startup 29 4 1 1 Using the Stylus 30 4 1 2 Touch Gestures 31 4 2 Windows CE Touch Screen Calibration 32 4 3 Data Capture 33 4 3 1 Laser Data Capture 34 4 3 2 Imager Data Capture 36 4 4 Desc...

Page 4: ...guration Utility 87 4 10 Datalogic Desktop Utility 88 4 10 1 Administrative Options Admin tab 89 4 10 2 Locked Web Browser Options LockedWeb tab 92 4 10 3 Status Icons Options Status Tab 97 4 10 4 Windows Controls 98 4 10 5 AppSelector Options AppSelect tab 100 4 11 AppSelector Application Selector 103 4 12 Locked Web Browser 104 4 12 1 Locked Web Browser Special Metatags 106 4 13 Autostart 110 4 ...

Page 5: ...v Industry Canada Compliance 143 SAR Compliance 145 WEEE Compliance 146 GLOSSARY 148 INDEX 152 ...

Page 6: ... Falcon X3 refer to the SDK Help on Line SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website Please check our website at www datalogic com under Support Services then Automatic Data Capture and click on the links indicated for further information including Downloads Manuals for the latest versions of user manuals and product guides Software Uti...

Page 7: ...OFF Power Key C LEDs D Microphone E Front Scan Key F Keyboard G Stylus H Laser Safety Label I Product Label J Loudspeaker K Reset Key under battery L MicroSD Card Slot under battery Remove protective film cover before use G C D B F A E H I J L K ...

Page 8: ...1 viii M Data Capture Window N Handylink Connector host slave Remove protective film cover before use M N ...

Page 9: ...d long range imager offer aggressive scanning solutions The parallel computer architecture of the Falcon X3 melds the strengths of an XScale PXA310 microprocessor with a Cortex M3 coprocessor This combination gears the device for real time information management Memory of 256 MB RAM 1 GB Flash accommodates multiple simultaneous applications for managing large databases or enabling off line autonom...

Page 10: ...phone key layout placing numeric keys at the device top with navigation scan and enter keys This highly functional layout places high use keys at the user s finger tips Maximized key sizes drive additional user efficiency with or without gloves A choice of crystal clear full VGA and QVGA displays and the back lit keyboard make the Falcon X3 readable in dark back corners or full sunlight The Falcon...

Page 11: ...re 945200030 FALCONX3 00A0HP 2N0 CEU1 Falcon X3 Hand held 802 11 a b g n CCX v4 Bluetooth v2 1 256MB RAM 1GB Flash QVGA 29 Key Numeric High Performance Laser w Green Spot Windows CE 6 0 945200031 FALCONX3 00A0WI 2N0 CEU1 Falcon X3 Hand held 802 11 a b g n CCX v4 Bluetooth v2 1 256MB RAM 1GB Flash QVGA 29 Key Numeric Standard Range Imager w Green Spot Windows CE 6 0 945200032 FALCONX3 00A0HP 2N1 ME...

Page 12: ...aser w Green Spot Windows CE 6 0 945250052 FALCONX3 00A0HP 3F0 CEU1 Falcon X3 Pistol Grip 802 11 a b g n CCX v4 Bluetooth v2 1 256MB RAM 1GB Flash QVGA 52 Key Alpha Numeric High Performance Laser w Green Spot Windows CE 6 0 945250053 FALCONX3 00A0XL 3N0 CEU1 Falcon X3 Pistol Grip 802 11 a b g n CCX v4 Bluetooth v2 1 256MB RAM 1GB Flash QVGA 29 Key Numeric Auto ranging Laser XLR Windows CE 6 0 9452...

Page 13: ...a 3 1MP WEHH 6 5 945250061 FALCONX3 00A0XL 3N1 MEN1 Falcon X3 Pistol Grip 802 11 a b g n CCX v4 Bluetooth v2 1 256MB RAM 1GB Flash VGA 29 Key Numeric Auto ranging Laser XLR Camera 3 1MP WEHH 6 5 945250062 FALCONX3 00A0XL 3F1 MEN1 Falcon X3 Pistol Grip 802 11 a b g n CCX v4 Bluetooth v2 1 256MB RAM 1GB Flash VGA 52 Key Alpha Numeric Auto ranging Laser XLR Camera 3 1MP WEHH 6 5 945250063 FALCONX3 00...

Page 14: ...1 FALCON X3 6 1 945250066 FALCONX3 00A0LR 3F1 MEN1 Falcon X3 Pistol Grip 802 11 a b g n CCX v4 Bluetooth v2 1 256MB RAM 1GB Flash VGA 52 Key Alpha Numeric Extended Range Imager XLR Camera 3 1MP WEHH 6 5 ...

Page 15: ...uter and to the network are packaged separately the cradle and or one or more connection cables Remove all the components from their packaging check their integrity and compare them with the packing documents Keep the original packaging for use when sending products to the technical assistance center Damage caused by improper packaging is not covered under the warranty CAUTION Rechargeable battery...

Page 16: ... a microSD memory storage card To access the microSD card slot and insert the card proceed as follows 1 Turn off the Falcon X3 2 Press the latch release and lift the battery from the enclosure as indicated in the figure below 3 Open the microSD card slot by pulling up the locking plate ...

Page 17: ...the steps above to access the SD area and remove it from its slot Follow proper ESD precautions to avoid damaging the SD Proper ESD precautions include but are not limited to working on an ESD mat and ensuring that the operator is properly grounded Do not force the card If you feel resistance remove the card check the orientation and reinsert it Do not use the microSD card slot for any other acces...

Page 18: ...ble USB Handylink Host 94A051972 Cable RS232 Handylink Client 94A051973 Cable RS232 Handylink Host 94A051975 Power Adapter 12 to 24V PWR Plug 2 1mm 94A051976 Adapter PWR Jack 2 1mm to Handylink Various 94ACC0104 Rubber Shell FalconX3 95ACC1056 Holster FalconX3 94ACC1371 Module Ethernet Single Slot Dock 94ACC1372 Module Modem Single Slot Dock 94ACC1388 Softcase FalconX3 94ACC1390 Handle Kit Falcon ...

Page 19: ... such as the frequency of barcode scanning RF usage battery life storage environmental conditions etc NOTE The battery icon on the Taskbar indicates when the battery pack is low It is possible to recharge the battery pack by connecting the power supply directly to the Falcon X3 Alternatively it is also possible to recharge the battery pack by inserting the Falcon X3 into the single slot dock or th...

Page 20: ...harge or very low charge We recommend charging the battery pack every two to three months to keep its charge at a moderate level to maximize battery life CAUTION Even if the storage temperature range is wider in order to achieve the longest battery life store the terminal and the spare batteries between 30 to 70 ºC 22 to 158 ºF Falcon X3 should be charged at an ambient temperature between 0 35º C ...

Page 21: ...d does not mean a malfunction NOTE Use only a USB IF compliant USB port as a charging source NOTE When the battery is very low the audio feature and the scanning feature of imager long range and XLR laser models are disabled They will be re enabled a few minutes after the charging starts NOTE ...

Page 22: ...the battery pack proceed as follows 1 Turn off the Falcon X3 2 Press the latch release and lift battery from the enclosure as indicated in the figure below 3 Install the new battery pack first insert the top end then the latch bottom as indicated in the following figure ...

Page 23: ...ontainers on induction cook surfaces or similar devices Doing so may cause the battery pack to generate heat explode or ignite Using the battery pack in this manner may also result in a loss of performance and a shortened life expectancy Use only a Datalogic approved power supply The use of an alternative power supply will void the product warranty may cause product damage and may cause heat an ex...

Page 24: ...vices which if damaged may cause the battery pack to generate heat explode or ignite In case of leakage of liquid from the battery avoid contact with liquid the skin or eyes If the contact occurs immediately wash the affected area with water and consult a doctor Do not solder directly onto the battery pack Do not expose the battery pack to liquids Avoid any knocks or excessive vibrations If the de...

Page 25: ...If the battery is not sufficiently charged the Falcon X3 will not turn on when the ON OFF Power button is pressed In this case either substitute a sufficiently charged battery insert the Falcon X3 into a powered cradle or plug it into a wall charger NOTE To maximize battery life turn off radios when they are not needed NOTE ...

Page 26: ...1 FALCON X3 18 2 2 3 CLEANING THE MOBILE COMPUTER Periodically clean the Falcon X3 with a slightly dampened cloth Do not use alcohol corrosive products or solvents ...

Page 27: ...talogic Handylink cable 94A051970 to directly connect the Falcon X3 to a host computer to transfer data through the USB interface Key A Host computer C Falcon X3 B 94A051970 Handylink USB Client Cable Connection through the cable complies to USB 2 0 standard NOTE A B C ...

Page 28: ... on insert the Falcon X3 into the dock Key A Host computer A 94A150057 Falcon X3 Single Slot Dock B A to B USB straight cable included in the box D 94ACC1381 Power Adapter Connection through the cradle complies to USB 2 0 standard NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical speed NOTE B D C A ...

Page 29: ...r with a standard A to micro A USB cable For all these devices maximum current withdrawal must be below 100mA Key A Keyboard with USB interface C 94A051969 Micro USB Host Cable 94A051971 Handylink Micro USB Host Cable B Falcon X3 D Standard A to Micro A USB Cable Key A USB hard drive external memory source C 94A051971 Handylink Micro USB Host Cable B Falcon X3 D Standard A to Micro A USB Cable A B...

Page 30: ...d A to Micro A USB Cable E 94ACC1381 Power Adapter C A to B USB straight cable included in the box Falcon X3 works with most of the mentioned USB peripherals In any case we can t guarantee the interoperability of Falcon X3 with all devices on the market NOTE Connection complies to USB 2 0 standard NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical speed NOTE ...

Page 31: ... X3 B 94A051972 Handylink Micro RS232 Client Cable The Single Slot Dock can be connected to the Host by means of a standard null modem cable such as Datalogic 94A051020 CAB 427 for 9 pin connections Once the Host has been turned on insert the Falcon X3 into the dock Key A Host Computer C 94A150057 Falcon X3 Single Slot Dock B 94A051020 CAB 427 RS232 Null Modem Cable D 94ACC1381 Power Adapter A B C...

Page 32: ...ost computer For models using the 802 11 a b g n radio you can find information about the applet for radio configuration http www summitdatacom com SCU htm To launch this utility you can tap the specific icon if it is visible on the taskbar or you can select the menu item Start Summit and tap the Summit Client Utility icon Key A Falcon X3 B Access point C Host Application Server A B C A ...

Page 33: ...nal resumes depending on the radio power mode and security protocol selected it may take up to 30 seconds for the 802 11 a b g n radio driver to re associate the radio to the network NOTE Area coverage and radio performance may vary due to environmental conditions access point types or interference caused by other devices microwave ovens radio transmitters etc NOTE In case of heavy usage the Falco...

Page 34: ...king the module must be powered on using the Wireless Manager applet see par 4 6 6 and perform the Discovery procedure see par 4 7 2 NOTE Suspending the terminal powers off the Bluetooth radio and drops the piconet Bluetooth connection When the terminal resumes it takes approximately 10 seconds for the Bluetooth radio driver to re initialize the radio NOTE Area coverage and Bluetooth radio perform...

Page 35: ...enty five 25 cm from their pacemaker and or any other medical device Should not carry this device in a breast pocket Should keep the device at the opposite side of the pacemaker and or any other medical device Should turn this device OFF or move it immediately AWAY if there is any reason to suspect that interference is taking place Should ALWAYS read pacemaker or any other medical device guides or...

Page 36: ...s improperly installed and the air bag inflates serious injury could result WARNING Turn off the device when in any area with a potentially explosive atmosphere Observe restrictions and follow closely any laws regulations warnings and best practices on the use of radio equipment near fuel storage areas or distribution fuel areas chemical plants or where some operation involves use of explosive mat...

Page 37: ... pack is installed use the ON OFF key to turn the mobile computer on and off As soon as the mobile computer is on the Windows CE 6 0 desktop will appear on the screen Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure Desktop Control Panel Use the stylus par 4 1 1 as suggested to select icons and options The mobile computer goes into power o...

Page 38: ...vailable for that item On the pop up menu that appears tap the action you want to perform To recalibrate the touch screen use the Stylus Applet see par 4 6 7 Use only original Datalogic styluses supplied with the product itself In harsh applications use of screen protectors should be taken into consideration in order to extend the touch screen operating life To prevent damage to the screen do not ...

Page 39: ...epresents the left click of a mouse Double Tap A double tap represents the left double click of a mouse Hold The user can press and hold on the screen to represent the right click of a mouse Flick The user can move a finger across the screen to initiate per pixel scrolling and if this movement is fast enough scrolling will continue after the finger is lifted Pan The user can press and hold on the ...

Page 40: ...stry to default values the mobile computer startup see par 4 1 is preceded by the touch screen calibration screen The touch screen calibration will also appear when the mobile computer is hard reset cold boot but the user may press Esc to exit from the calibration The user must calibrate the touch screen see par 4 6 7 Touch Screen Calibration Screen ...

Page 41: ...USE AND FUNCTIONING 33 4 4 3 DATA CAPTURE To capture data tap Start Settings Control Panel double tap Decoding To configure and enable data capture parameters refer to par 4 6 1 ...

Page 42: ... pressing the SCAN key or the pistol trigger The lighted band emitted by the laser must completely cross the barcode as shown in the figure below If the scan has taken place correctly the Good Read LED glows steadily Green for a configurable time if enabled the Good Read Beep plays if enabled the GreenSpot projects a green spot onto the bar code image ...

Page 43: ...USE AND FUNCTIONING 35 4 Remove the protective film cover over the Laser Output Window before use NOTE ...

Page 44: ...ode and press the SCAN Key or the pistol trigger The Falcon X3 Imager uses an intelligent aiming system pattern similar to those on cameras indicating the field of view which should be positioned over the code Aiming System If the aiming system pattern is centered over the entire symbology as shown in the following figure either wait for the timeout or release the Scan key or the trigger to captur...

Page 45: ...Falcon X3 Imager is closer to the code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit See par 5 1 for further details If the scan has taken place correctly the Good Read LED glows steadily Green for a configurable time if enabled t...

Page 46: ... 4 DESCRIPTION OF THE KEYS The Falcon X3 comes with three different keyboards A 52 key alphanumeric keyboard A 52 key keyboard specific for Terminal Emulation A 29 key numeric keyboard 4 4 1 52 Key Alphanumeric Keyboard ...

Page 47: ...ithin text fields scroll through a Menu list or browse among folder files Yellow modifier toggle key when pressed before a standard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a standard key it enables the character or function printed in blue above the key It powers the Falcon X3 on or off it is placed on the upper left s...

Page 48: ...1 FALCON X3 40 4 4 4 2 52 Key Terminal Emulation 5250 Keyboard ...

Page 49: ...Menu list or browse among folder files Yellow modifier toggle key when pressed before a standard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a standard key it enables the character or function printed in blue above the key It powers the Falcon X3 on or off it is placed on the upper left side of the terminal ...

Page 50: ...1 FALCON X3 42 4 4 4 3 Numeric Keyboard ...

Page 51: ...Menu list or browse among folder files Yellow modifier toggle key when pressed before a standard key it enables the character or function printed in yellow above the key Blue modifier one shot key when pressed before a standard key it enables the character or function printed in blue above the key It powers the Falcon X3 ON or OFF It is placed on the upper left side of the terminal ...

Page 52: ...n both the registry and the file system returns to a clean status that conforms to factory default Warm Boot To perform a warm boot press and hold the following keys simultaneously Cold Boot To perform a cold boot do the following steps 1 Turn off the Falcon X3 by pressing the on off key 2 Pull the battery latch down and remove the battery pack 3 Press and hold the scan button and then press the r...

Page 53: ...SE AND FUNCTIONING 45 4 Warm Boot Cold Boot Clean Boot Registry Restored from flash Restored from flash Clean configuration no user config File System Preserved Preserved Clean Installation no user files ...

Page 54: ...ull charge Red It is solid while charging Red blinking It blinks in case of charge fault Keyboard Status center Off Keyboard in primary Yellow solid Yellow alternate key mode Blue solid Blue alternate key mode Pink CapsLock enabled Good Read right side Red Scanning LED is ON from the time the user hits the scan button Trigger until the bar code is decoded laser models Time out imager models Green ...

Page 55: ...p it to open a status dialog that will let you disconnect the ActiveSync session without physically disconnecting the device from the PC It is the only way to disconnect a Bluetooth ActiveSync connection Battery icon displays the system battery status It indicates that the battery is charging Bluetooth Manager icon displays whether Bluetooth is enabled paired or turned off Double tap this icon to ...

Page 56: ...1 FALCON X3 48 4 4 6 CONTROL PANEL From the Start menu tap Settings then Control Panel Below is an expanded view of the Control Panel showing all of the applets Windows CE Control Panel ...

Page 57: ...iguration pages and multiple Barcode symbology pages DECODING CONFIGURATION PAGES Select the desired configuration from the options shown in the figure below and the other Decoding Properties figures on the following pages Select General 1D Bar Code or 2D Bar Code then use the menu or tap the left and right arrow keys to navigate the different pages of the Decoding utility The menu options will ch...

Page 58: ...l Notification Use it to set volume tone duration and number of various types of beeps Good Read From the Decoding Properties page tap Configure General Good Read Use it to enable Good Read indications the use of Green Spot the LED and a to set the decoding timeout for decoding labels ...

Page 59: ...ap Configure General Formatting Use it to configure prefix suffix and data separator character strings General Options From the Decoding Properties page tap Configure General General Options Select from Label Programming Enable Symbology IDs and Group Separator Replacement ...

Page 60: ...ding Properties page tap Configure General Decoding Options Use it to configure the User ID for symbologies Redundancy and Aggressive Decoding if supported by the decoding module Select a symbology to view or change the available properties settings ...

Page 61: ... Properties page tap Configure General Spot Beam It allows enabling and configuration of Spot Beam and triggering modes It is only available on devices equipped with laser and advanced long range laser decoding modules that support the Spot Beam Feature ...

Page 62: ... page tap Configure General Scanning Options It configures the scan width and allows to enable the automatic range detection Devices From the Decoding Properties page tap Configure General Devices Use it to enable or disable the keyboard wedge for Barcode scanner ...

Page 63: ...row keys to navigate the different pages of the barcode symbology pages Select Configure 1D Bar Code from the menu to view other configuration options Each barcode symbology opens to its own page as shown in the figure below Refer to the sample symbology control panels for examples of the types of fields and options you can modify ...

Page 64: ...faults Minimum Settings Maximum Settings Save New Settings Revert to Saved Settings The settings are saved when you tap Yes To permanently save these settings you need to save the Registry using the Persistent Registry applet in the Control Panel When open Decoding Properties acts as a simple barcode test tool that provides the Data decoded and the Data Type of the barcode scanned ...

Page 65: ...with specific applications From the control panel main window double tap the DL Buttons icon On the DL Buttons tab customize the program hardware buttons to launch your most used applications Under Select a button select the button you want to assign a function to and then select a program from Assign a function ...

Page 66: ...cannot delete the following buttons Alt 6 Left Button Pistol Trigger Right Button Scan Assign a function This pull down list displays the available functions Application Displays path to the selected application Browse Select tap to browse for application files You can associate an executable program with the specified Button Arguments Type the command line arguments that are needed for the specif...

Page 67: ...ey combination in the Add Key textbox COMMAND DESCRIPTION Enter Key Enter the desired key combination in this text box to define a Button OK Select tap OK to add the specified Button X Select tap X to cancel the specified Button Make sure you do not attempt to add a Button that is already defined NOTE 2 Select tap OK to save the new Button If you select tap X the key will not be saved ...

Page 68: ...possible for the keyboard wedge to activate assigned Buttons using alphanumeric characters Barcodes containing characters associated with assigned Buttons will trigger the action or application assigned to that Button CAUTION ...

Page 69: ...ers Triggers are special customizable buttons that are mapped by default by DL Buttons Also they can be set as wakeup buttons TRIGGERS DEFAULT CONFIGURATION Assigned Function Wake up Scan Bar Code Disabled Pistol Trigger Bar Code Enabled ...

Page 70: ...open applications The application switcher can be activated via an assigned shortcut key specified in the DL Buttons tab see par 4 6 2 When the assigned button is pressed the dialog shown below will be displayed Press the assigned button to cycle through the running applications when the dialog is open Press Enter to switch to the selected application or Esc to close the application switcher ...

Page 71: ...pplications and hardware devices The Registry also contains information that the operating system continually references to during operation To persist the Registry settings between boots do the following steps 1 Select Start Settings Control Panel 2 Double tap the Persistent Registry icon 3 Tap the Persist button 4 Tap OK to exit ...

Page 72: ...3 64 4 To change Persistent Registry timing do the following steps 1 Select Start Settings Control Panel 2 Double tap the Persistent Registry icon 3 Select a time interval from the menu 4 Tap OK to save and exit ...

Page 73: ...G 65 4 To deselect Persistent Registry timing do the following steps 1 Select Start Settings Control Panel 2 Double tap the Persistent Registry icon 3 Deselect the Persist Registry settings box 4 Tap OK to save and exit ...

Page 74: ... Wireless networking has a customized control Summit Client Utility SCU specific to the radio There are two methods to access the SCU Start Programs Summit SCU Or From the Control Panel main window double tap Wi Fi to open the Summit Client Utility ...

Page 75: ...ll open to the Main tab Summit Client Utility 1 To create a new profile tap the Profile tab Information about the wireless network can be entered directly in the profile tab or by pressing Scan when the desired network ESSID is in range ...

Page 76: ...elect the desired SSID 3 Click the Configure button 4 Follow the on screen instructions to setup security parameters for your network For more detailed settings specific to your installation please contact your wireless network administrator ...

Page 77: ...he Main tab if you have not previously selected Commit you will be prompted to save your changes At the Main tab select the profile you just created If you used the scan button the desired profile will have the same name as the ESSID Use the Status tab to check connectivity to the network ...

Page 78: ...1 FALCON X3 70 4 More detailed information about the applet for radio configuration can be found at http www summitdata com SCU htm ...

Page 79: ...hen you attempt to select one item with the stylus another item is erroneously selected To recalibrate the touch screen complete the following steps 1 From the Control Panel main window double tap Stylus to open the Stylus Settings dialog 2 Tap Calibration to open the Calibration screen Tap Recalibrate ...

Page 80: ...ibration settings 5 New calibration settings are persistently saved in the Registry Startup Stylus Calibration When starting the terminal a Welcome Wizard with Stylus Calibration comes up if valid calibration settings are not available This happens in the following circumstances 1 At the first startup of the terminal 2 After any cold boot if the user skipped stylus calibration earlier 3 After a Cl...

Page 81: ...rom the control panel main window select the Audio applet by double tapping the Audio icon The audio control panel can be used to independently set the playback or recording volume for different types of audio inputs and outputs such as a headset powered mobile dock or the internal speakers and microphone Audio Windows ...

Page 82: ...From the control panel main window select the Volume Sounds applet by double tapping the Volume Sounds icon The Volume Sounds applet configures audio features of all speakers and headphones and appears as follows Volume Sounds Window ...

Page 83: ...have to download Microsoft ActiveSync You can establish a connection to your Falcon X3 through the following interfaces USB either directly or through the Single Dock RS232 either directly or through the Single Dock Bluetooth see par 4 7 2 To establish a partnership between the Falcon X3 and a host PC start Windows Mobile Device Center and follow the steps below 1 Connect the Falcon X3 to the host...

Page 84: ...Windows CE does not come equipped with Microsoft Office Outlook or any other application that allows users to view contact calendar e mail or task data Users can view files copied to the Falcon X3 by WMDC s file synchronization feature NOTE ...

Page 85: ...uetooth Manager control panel tap Connections 2 Search for available Bluetooth devices by tapping the button for the type of device you want Printer Serial or All or tap Discovery Discover to skip this step The Falcon X3 will search for Bluetooth devices within range If you attempt to set up a connection when the Bluetooth radio is disabled you will receive a message reminding you that the radio i...

Page 86: ... displayed in the Discovery tab You can set up a connection to a device in the list by selecting the device and then tapping the Connect button To create a pairing 1 Select a service 2 Configure any encryption authentication or virtual port options required by the service selected ...

Page 87: ...Interface Device HID Keyboard Serial Personal Area Network PAN Modem Headset Handsfree Virtual Port allows you to specify the incoming port which is used to communicate serially with an incoming device just as if it were a physical COM port This option is available only if you have selected a Printer or Serial service ...

Page 88: ...tings 1 To require Authentication check the checkbox then tap OK 2 If required the Authentication Request dialog will then open requesting that you enter a PIN Use the Input Panel or the keyboard to type the PIN 3 Tap OK to complete The dialog will also appear when an Authentication request is received from another device ...

Page 89: ...airing you can view the settings by double tapping its name from the Connections tab Tap the arrow to change the Virtual Port or Delete to remove the device pairing Tap Sync to initiate a Sync available only if the service is an ActiveSync connection ...

Page 90: ...within close range and that both Bluetooth enabled devices are discoverable 1 From the control panel main window double tap the Bluetooth Manager icon to open the Bluetooth Manager control panel 2 Tap Settings The Settings tab allows you to enable or disable the Bluetooth radio and specify settings for Incoming Connections ...

Page 91: ...rol to select a virtual COM port to use for the connection 5 Tap Find Me if you want to make the FalconX3 discoverable to other Bluetooth devices for 60 seconds allowing them to set up a connection By default Bluetooth is turned off If you turn it on and then turn off your device Bluetooth also turns off When you turn on your device again Bluetooth turns on automatically NOTE ...

Page 92: ...ice downloads If Wavelink Avalanche is not available or you have only a few Datalogic devices to update use the Datalogic Firmware Utility DFU described below to install or update the firmware using an ActiveSync connection The following sections provide procedures for the retrieval and installation of the most current firmware image onto a Datalogic device 4 8 1 Retrieving a Firmware Image Update...

Page 93: ... to installing you must remove any previous versions of DFU installed on the host PC NOTE To install the Datalogic Firmware Utility complete the following steps on the PC 1 Go to the Datalogic website and download the most current version of the Datalogic Firmware Utility Unzip the file then double click to run DFU_Setup exe 2 Click OK to continue once you have removed previous versions of DFU 3 T...

Page 94: ... Datalogic DFU Datalogic Firmware Utility 2 Verify that ActiveSync is selected by clicking Communications WMDC ActiveSync 3 Click browse and navigate to the location where you saved the firmware file for your terminal 4 Select the current out file and click Open 5 Click Update 6 DFU will compare the selected firmware image with the firmware already loaded on the device if the image is compatible w...

Page 95: ... ActiveSync and then click on the Get from Device icon to receive the device s current configuration Once loaded the Configuration Tree on the left side of the window is used to navigate the device s configuration The right side of the window is a work area where the values of different parameters may be set for each branch of the configuration tree Click on the parameter group branch to open it a...

Page 96: ...ns Restrict user access in Internet Explorer Set up configuration and customized error recovery mechanisms Create quick access hot keys and configure trigger actions To open DDU for the first time tap Start Settings Control Panel or Start Programs Device tools and then double tap the icon for Datalogic Desktop Utility You can also open DDU by pressing the appropriate key shortcut The default is Al...

Page 97: ... specify a password when this utility is launched By default the password is 1234 A password can consist of all standard keyboard characters Re Enter Password Carefully re enter the password in the second text box Set Password Select tap Set Password to enable the password To change or remove the password enter a new value re enter the new value and select tap Set Password Set Defaults Select tap ...

Page 98: ...ct tap OK to close the Set Password Confirmation dialog You must select tap Set Password prior to exiting DDU in order to store and activate your new password It is not necessary to select Enable Datalogic Desktop NOTE If you select tap Set Defaults it will remove all custom settings and restore all the factory default settings except a previously set password CAUTION Changing a Password To change...

Page 99: ...ext time you open the Datalogic Desktop Utility the DDU Password dialog box opens This dialog box will only open if a password was defined 1 Type in your password using either the keypad on the unit or using the stylus on the soft input panel SIP If you enter an incorrect password the system will prompt you to input the correct one 2 Select tap OK to verify the password Or tap X to cancel ...

Page 100: ...he next page for more information NOTE For additional information about Locked Web Browser commands and metatags see section 4 12 Locked Web Browser Error Page Redirection Use the Error Redirection option to provide customized recovery from common errors When an error occurs the browser can redirect access to a specified error page with instructions on how to recover from the problem Locked Web Co...

Page 101: ...ressing Ctrl O to Open a File will not work safe key presses e g Alpha numeric will still get processed by the Locked Web Browser as normal For example entering a number in a text field on a web page DL Buttons keys will not work in the LockedWeb Browser all Locked Web Browser command keys will work e g Ctrl 0 to exit When unchecked all keys will be processed normally by the system and the browser...

Page 102: ...1 FALCON X3 94 4 Advanced Settings General Tab Context Menu ...

Page 103: ... List Enables a white list which restricts browsing only to files and URLs in the Allowed Website list accessed by the button The following dialog appears Allowed Website List Click the Add button to add allowed URLs to the white list Other sites will be restricted when the option is enabled Domain names must be exactly specified Change Exit Password Pressing this button brings up a dialog which a...

Page 104: ...ialog Zoom WEHH only Adds a Zoom item to the Locked Web Browser context menu Selecting the item brings up the IE Zoom Tool Back Adds a Back item to the Locked Web Browser context menu Selecting the Back item performs a navigation to the previous page Home Adds a Home item to the Locked Web Browser context menu Selecting the Home item navigates to the IE home page Minimize Adds a Minimize item to t...

Page 105: ...re used in LockedWeb and in Application Selector to display the status of Wi Fi radio battery and GSM The GSM status icon feature is available only on devices that support GSM NOTE Status Icons Options Set Status Icon Defaults Restores the status icons factory settings Icon Size Sets the status icons size Icon Location Selects the preferred location for each status icon ...

Page 106: ...ols to allow or restrict access to Windows system functions You can disable normal Windows functions such as the taskbar leaving nothing but a blank workspace This allows applications to be run in full screen mode and prevents users from accidental or unauthorized use of the taskbar Internet Explorer and any other resident applications ...

Page 107: ...ify whether the Start Menu is displayed or not This option works only when Task Bar Enabled is checked AutoSIP Enabled Enables the AutoSIP Windows feature Scroll Bars Enabled This control only takes effect in Locked Web Browser When checked displays horizontal and vertical scroll bars to help view large web pages which do not fit the screen When unchecked scroll bars will not be present Windows CE...

Page 108: ...lector replaces the desktop and allows only authorized use of applications Show status icons Enable or disable the status icons view see par 4 10 3 The status icons can be configured on the Status tab of DDU Authorized Applications This is a list of applications that the user can access Application Selector Commands New Select tap New to create a new application entry Edit Select tap Edit to edit ...

Page 109: ...ON Application Title Type the name of the application in this textbox in the way you wish it to appear for the user Executable Displays the path for the executable file which you want to run Browse Select tap to browse for the desired executable file The results of this search are placed in the Executable textbox Arguments Type any command line arguments to be used when an application is executed ...

Page 110: ...lector starts up Applications will be started in the order listed in the authorized application list Delay Enter a delay duration in seconds in the combo box This option delays auto start of application s to allow drivers to load prior to starting applications OK Select tap OK to add save changes X Select tap X to cancel the creation of this entry ...

Page 111: ...of applications By default the Application Selector comes with no applications preset Figure 9 Application Selector The administrator can customize this list as shown in chapter 4 10 5 To run an application tap on its name Additionally the page template can be modified to display a different background Contact your Datalogic representative for more information on this feature To exit from Applicat...

Page 112: ...t This means users can only access web applications and websites set by the administrator Configuration is set up through the DDU control panel See section 4 10 2 for more information NOTE CE Mode A non full screen mode allows the status bar to be displayed but with user interaction disabled While in these modes the user can navigate within the web application by using the following keyboard short...

Page 113: ... the following command line arguments are supported E optional parameter which allows for Exit without entering a password URL optional parameter which specifies a URL to use as a home page C optional parameter which disables the ctrl keys including the one to exit ...

Page 114: ...The Datalogic Locked Web Browser defines some special metatags that allow the web application to interact with the device In particular the special metatags allow it to enable disable scan engine triggers enable disable specific symbologies in the scan engine easily assign a key press to a javascript function Metatag settings of trigger enable symbology enable or DL_Key assignments persist past th...

Page 115: ... javascript function that receives one parameter the serial number An example would be function CustomerFunction SerialNumber Reboot Warm Boot Device Metatag DL_Reboot Warm boot device Content OnPageLoad Warm boot immediately upon page load Example meta http equiv DL_Reboot content OnPageLoad Exit Metatag DL_Exit Exit the Locked Web Browser Content OnPageLoad Exit immediately upon page load If Exi...

Page 116: ...e_M25 DL_Code_CODABAR DL_Code_93 DL_Code_UPCA DL_Code_UPCE DL_Code_EAN13 DL_Code_EAN8 DL_Code_MSI DL_Code_MSR DL_Code_GS1_14 DL_Code_GS1_LIMIT DL_Code_GS1_EXP DL_Code_PDF417 DL_Code_DATAMATIX DL_Code_MAXICODE DL_Code_TRIOPTIC DL_Code_PHARMA39 DL_Code_RFID DL_Code_MICROPDF417 DL_Code_COMPOSITE DL_Code_QRCODE DL_Code_AZTEC DL_Code_POSTAL Examples meta http equiv DL_Code_39 content Disable meta http ...

Page 117: ...library aa243025 VS 60 aspx Because DL_Keys persist past the page in which they were loaded the DL_Clear metatag is provided to clear the settings on subsequent page loads NOTE Scanning Metatags DL_Scan Captures scan results and sends barcode tag value to a javascript function on the web page If the content value is a javascript function the device will be taken out of keyboard wedge mode and star...

Page 118: ...ng each line with the specified command line arguments It will take into account any AutoStart options at the beginning of the line Upon a Cold Boot AutoStart installs all the CAB files located in the CAB folder If the CAB folder does not exist no CAB files will be installed AutoStart will then run the Autostart ini from the root directory executing each line with the specified command line argume...

Page 119: ...e device CAUTION CAB files are installed by AutoStart using the Wceload exe application The following table shows available command line option Option Description noui Specifies that you will not be prompted for any input during the installation If the CAB file is signed any responses will automatically be answered Yes If the CAB is unsigned then any responses will be answered No silent Suppresses...

Page 120: ...ould be placed in the AutoStart folder with other CAB files intended for installation on the next reboot 4 13 4 Autostart ini A file named PreAuto ini can also be created in addition to or instead of Autostart ini PreAuto ini is executed before CAB files in the Cab folder are installed Autostart ini is executed after CAB files in the Cab folder are installed The format for the PreAuto ini is ident...

Page 121: ... each component of the line in the Autostart ini If the executable path is in a folder that contains spaces in the name quotes are required to distinguish what the actual executable name is The following is an example of this Program Files ScannerApp exe run valid Program Files ScannerApp exe run invalid The second line is an invalid line because there is no way to distinguish the executable from ...

Page 122: ...s elsewhere it is ignored Do not wait on line completion This will cause the line to execute and immediately move onto the next line Query Request user confirmation when running the executable This will halt parsing the Autostart ini until the confirmation is answered This is intended for debugging the Autostart ini file Execute only on Cold Reset Execute only after a warm boot Cold Reset Only Thi...

Page 123: ... on the current line to complete execution Query Option The query option is intended for use when debugging the autostart ini When a line with this option is executed the following dialog will appear with the specified executable and command line arguments The populated fields shown in the AutoStart Execute Query are described the next table Field Description Line Number This is the line number in...

Page 124: ...ed to surround the given field and make it very clear what the value of the field is The following table describes the results of each choice Button Action Yes The current line will execute No The current line will not execute AutoStart will continue parsing the Autostart ini Cancel The current line will not execute and AutoStart will discontinue parsing the Autostart ini ...

Page 125: ...xecute Program with the argument Files App exe Program Files App exe run invalid This will execute Program with the argument Files App exe run Program Files App exe run This will execute the program Program Files App exe with the argument run Windows Pword exe This will confirm the execution of Windows Pword exe If the execution is confirmed AutoStart will immediately process the next line Program...

Page 126: ... only 8 9 cm 3 5 in diagonal 65K colors backlight touch screen KEYBOARD Polycarbonate hard cap keyboards with backlight 29 key numeric or 52 key alpha numeric with discrete navigation OPERATING TEMPERATURE 20ºC to 50ºC 4ºF to 122ºF STORAGE TEMPERATURE 30 to 70 ºC 22 to 158 ºF DROP RESISTANCE Withstands drops from 1 8 m 6 0 ft onto concrete and 1500 random drops from 1 0 m 3 3 ft according to IEC68...

Page 127: ...amping under software control POWER SUPPLY Removable battery pack with rechargeable Li ion batteries 3 7 V 5200 mAh 19 2 Watt hours COMMUNICATIONS INTERFACES Main connector with USB 1 1 Host USB 2 0 Hi Speed Client RS 232 up to 115 2 Kbps Ethernet via single slot or multi slot docks external modules LOCAL AREA NETWORK LAN Laird Summit IEEE 802 11 a b g n Frequency range Country dependent typically...

Page 128: ...MAGER CHARACTERISTICS Standard Range Imager 2D with Green Spot Extra Long Range Imager 2D XLR SCANNING RATE 60 frames sec maximum MINIMUM RESOLUTION 2D Linear codes 5 mils 2D codes 6 7 mils 2D XLR Linear codes 5 mils 2D codes 10 mils DEPTH OF FIELD 2D 2 to 60 cm 1 to 24 in depending on bar code size and density 2D XLR 17 to 952 cm 7 to 375 in depending on bar code size and density BAR CODES PDF417...

Page 129: ...Datalogic SDK C C NET Java Wavelink Studio MCL Collection Java Virtual Machine TERMINAL EMULATION Wavelink Terminal Emulation pre licensed Wavelink Industrial Browser CONFIGURATION MAINTENANCE Wavelink Avalanche pre licensed Avalanche Remote Control Datalogic Firmware Utility DFU Datalogic Desktop Utility DDU Datalogic Configuration Utility DCU SECURITY Wavelink SecurePlus Wavelink Certificate Man...

Page 130: ...il Code 128 1 97 in 4 99 cm 5 0 mil Code 39 2 5 1 7 47 in 18 96 cm 7 5 mil Code 39 2 5 1 15 67 in 39 79 cm 10 mil Code 128 14 77 in 37 51 cm 13 mil 100 UPC 22 62 in 57 45 cm 15 mil Code 128 23 87 in 60 62 cm 20 mil Code 39 2 2 1 41 87 in 106 34 cm 55 mil Code 39 2 2 1 75 37 in 191 43 cm 100 mil Code 39 3 0 1 reflective 178 87 in 454 32 cm ...

Page 131: ...de 39 2 5 1 14 37 in 36 49 cm 10 mil Code 39 2 5 1 29 37 in 74 59 cm 15 mil Code 39 2 5 1 49 37 in 125 39 cm 20 mil Code 39 2 2 1 69 37 in 176 19 cm 40 mil Code 39 2 2 1 149 37 in 379 39 cm 55 mil Code 39 2 2 1 169 37 in 429 89 cm 70 mil reflective Code 39 3 1 299 37 in 760 39 cm 100 mil reflective Code 39 3 1 431 37 in 1095 67 cm ...

Page 132: ...ranteed Working Ranges 5 0 mil Code 39 6 21 in 15 77 cm 6 67 mil PDF417 5 61 in 14 25 cm 7 5 mil Code 39 9 01 in 22 88 cm 10 mil PDF417 8 41 in 21 36 cm 13 mil UPC A 13 61 in 34 57 cm 15 mil PDF417 12 61 in 32 02 cm 15 mil Data Matrix in n a cm n a 20 mil Code 39 21 21 in 53 87 cm ...

Page 133: ...1 in 581 94 cm 100 mil Code 39 359 11 in 912 14 cm 70 mil Reflective Code 39 287 11 in 729 26 cm 100 mil Reflective Code 39 Note 3 359 11 in 912 14 cm Data Matrix 10 mil 23 11 in 58 7 cm Data Matrix 55 mil 129 11 in 327 94 cm Data Matrix 100 mil 209 11 in 531 14 in Mount reflective bar codes on white or black background with minimum 4 border Luminance in the line of sight direction should be 50 12...

Page 134: ...1 FALCON X3 126 6 6 TEST CODES High Density Codes 0 25 mm 10 mils Code 39 17162H 17162 2 5 Interleaved Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 80 EAN 13 x 0B2DE5 KKKKLM 80 EAN 8 6450 TRMN ...

Page 135: ...TEST CODES 127 6 Medium Density Codes 0 38 mm 15 mils Code 39 17162H 17162 Interleaved 2 5 Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 100 EAN 13 x 0B2DE5 KKKKLM 100 EAN 8 6450 TRMN ...

Page 136: ...1 FALCON X3 128 6 Low Density Codes 0 50 mm 20 mils Code 39 17162H 17162 Interleaved 2 5 Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 120 EAN 13 x 0B2DE5 KKKKLM 120 EAN 8 6450 TRMN ...

Page 137: ...TEST CODES 129 6 2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example PDF417 Example QR Code Example MAXICODE Example ...

Page 138: ...e of the Falcon X3 mobile computer disposal must be performed in compliance with the laws in force in your jurisdiction Before using the devices and the battery packs read par 2 Do not submerge the Falcon X3 in liquid products For further information refer to this manual and to the Datalogic website www datalogic com POWER SUPPLY This device is intended to be connected to a UL Listed CSA Certified...

Page 139: ...SER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure This information applies to both laser models and the Falcon X3 Imager Aiming System Laser output ...

Page 140: ...igura LUCE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MASSIMA POTENZA DI USCITA 1 mW LUNGHEZZA D ONDA EMESSA 630 680 nm CONFORME A EN 60825 1 2007 LASERSTRAHLUNG NICHT IN DER STRAHL BLINKEN PRODUKT DER LASERKLASSE 2 MAXIMALE AUSGANGLEISTUNG 1 mW WELLENLÄNGE 630 680 nm ENTSPR EN 60825 1 2007 RAYON LASER EVITER DE REGARDER LE RAYON APPAREIL LASER DE CLASSE 2 MAXIMUM PUISSANCE DE SORTI...

Page 141: ...posure to hazardous visible laser light CAUTION The product utilizes a low power laser diode Although staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid that the laser beam hits the eye of an observer even through reflective surfaces such as mirrors etc Use of optical system...

Page 142: ...ggio laser così come si eviterebbe qualsiasi altra sorgente di luminosità intensa ad esempio il sole Evitare inoltre di dirigere il raggio laser negli occhi di un osservatore anche attraverso superfici riflettenti come gli specchi L uso di strumenti ottici assieme allo scanner può aumentare il pericolo di danno agli occhi Tali strumenti ottici includono cannocchiali microscopi occhiali e lenti di ...

Page 143: ...gen eines Beobachters noch gegen reflektierende Oberflächen zu richten Die Verwendung von Optiksystemen mit diesem Scanner erhöht die Gefahr einer Augenbeschädigung Zu optischen Instrumenten gehören unter anderem Ferngläser Mikroskope Brillen und Vergrößerungsgläser ACHTUNG FRANÇAIS Les informations suivantes sont fournies selon les règles fixées par les autorités internationales et se réfèrent à ...

Page 144: ...L Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción CDRH 21 CFR 1040 y EN 60825 1 No es necesario abrir el aparato para la instalación la utilizac...

Page 145: ...o el sol Además eviten de dirigir el rayo láser hacia los ojos de un observador también a través de superficies reflectantes como los espejos El uso de sistemas ópticos con el escáner aumentará el riesgo de daños oculares Los instrumentos ópticos incluyen binoculares microscopios lentes y lupas ATENCIÓN LED CLASS LED illuminator integrated in the Falcon X3 models with imager engines are compliant ...

Page 146: ...i 1999 5 EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele English Hereby Datalogic ADC S r l declares that this FALCONX3 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Español Spanish Por medio de la presente Datalogic ADC S r l declara que el FALCONX3 cumple con los requisitos esenciales y cualesquiera ot...

Page 147: ...postanowieniami Dyrektywy 1999 5 EC Portuguê s Portuguese Datalogic ADC S r l declara que este FALCONX3 está conforme com os requisitos essenciais e outras disposições da Directiva 1999 5 CE Slovensk o Slovenian Datalogic ADC S r l izjavlja da je ta FALCONX3 v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999 5 ES Slovensk y Slovak Datalogic ADC S r l týmto vyhlasuje ž...

Page 148: ...gestion des appareils à radio fréquence de votre pays pour vérifier d éventuelles restrictions ou licences Pour tout renseignement vous pouvez vous adresser au site web http ec europa eu enterprise sectors rtte documents contacts points spectr DEUTSCH Wenden Sie sich an die für Radiofrequenzgeräte zuständige Behörde Ihres Landes um zu prüfen ob es Einschränkungen gibt oder eine Lizenz erforderlich...

Page 149: ...harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate ...

Page 150: ...enna the lower the power output While there may be differences between the SAR levels of various devices and at various positions they all meet the government requirement The FCC has granted an Equipment Authorization for this model device with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines SAR information on this model device is on file with the FCC and can...

Page 151: ... should also be advised that high power radars are allocated as primary users i e priority users of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars could cause interference and or damage to LE LAN devices Ce dispositif est conforme à la norme CNR 210 d Industrie Canada applicable aux appareils radio exempts de licence Son fonctionnement est sujet aux deux conditions suivantes 1 le ...

Page 152: ...rraient causer du brouillage et ou des dommages aux dispositifs LAN EL IMPORTANT NOTE IC Radiation Exposure Statement This EUT is compliant with SAR for general population uncontrolled exposure limits in IC RSS 102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528 This equipment can be installed and operated with minimum distance of 1 5 cm between...

Page 153: ... FCC guidelines for human exposure to radio frequency electromagnetic fields IC RSS 102 Issue 4 Radio Frequency RF Exposure Compliance of Radiocommunication Apparatus All Frequency Bands The portable device FalconX3 from Datalogic complies with the following European standards EN 50360 2001 AC 2006 A1 2012 EN 62209 1 2006 EN 62209 2 2010 EN 62311 2008 ...

Page 154: ...timento contattare il Fornitore dal quale è stata acquistata l apparecchiatura o consultare la sezione dedicata sul sito www datalogic com Information for the user in accordance with the European Commission Directive 2002 96 EC At the end of its useful life the product marked with the crossed out wheeled wastebin must be disposed of separately from urban waste Disposing of the product according to...

Page 155: ...sechos urbanos Eliminar este producto de accuerdo con la Directiva permite de evitar posibles consecuencias negativas para el medio ambiente y la salud derivadas de una eliminación inadecuada recuperar los materiales obteniendo así un ahorro importante de energía y recursos Para obtener una información más detallada sobre la eliminación por favor póngase en contacto con el proveedor donde lo compr...

Page 156: ...binary form The general format of a barcode symbol consists of a leading margin start character data or message character check character if any stop character and trailing margin Within this framework each recognizable symbology uses its own unique format Baud Rate A measure for data transmission speed Bit Binary digit One bit is the basic unit of binary information Generally eight consecutive bi...

Page 157: ...ork card automatically implies Ethernet Defined by the IEEE as the 802 3 standard Ethernet is used to connect computers in a company or home network as well as to connect a single computer to a cable modem or DSL modem for Internet access Firmware Firmware is a software program or set of instructions programmed on a hardware device It provides the necessary instructions for how the device communic...

Page 158: ...l light to reflect their information to the user Null modem cable RS 232 serial cable where the transmit and receive lines are crosslinked In some cables there are also handshake lines crosslinked In many situations a straight through serial cable is used together with a null modem adapter The adapter contains the necessary crosslinks between the signals Pairing A Bluetooth pairing occurs when two...

Page 159: ...t allows a device to be added without an adapter card and without rebooting the computer the latter is known as hot plugging The USB standard developed by several major computer and telecommunications companies supports data transfer speeds up to 12 megabits per second multiple data streams and up to 127 peripherals WLAN A Wireless Local Area Network links devices via a wireless distribution metho...

Page 160: ...iguration 49 Datalogic Configuration Utility 86 Datalogic Desktop Utility 87 Datalogic Firmware Utility 83 Description of the Keys 38 DL Buttons 57 F Falcon X3 Description 1 FCC Compliance 139 G General View vii Glossary 144 I Industry Canada Compliance 141 L Laser Safety 130 LED Class 136 LED Status 46 M MicroSD Card Insertion 7 P Package Contents 6 Persistent Registry 63 Power Supply 129 R Radio...

Page 161: ...echnical Features 118 Test Codes 125 Touch Gestures 31 U Using the Stylus 30 W WEEE Compliance 142 Windows CE Touch Screen Calibration 32 Windows Mobile Device Center 75 Wireless and Radio Frequencies Warnings 27 Wireless Communications 66 ...

Page 162: ...ompliance of the products to the following standards Cette déclaration de conformité est établie sous la seule responsabilité du fabricant et repose sur la conformité des produits aux normes suivantes Diese Konformitätserklärung wurde unter alleiniger Verantwortung des Herstellers ausgestellt und basiert darauf daß das Produkt den folgenden Normen entspricht La presente declaración de conformidad ...

Page 163: ...EN 62209 1 2006 HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND HELD AND BODY MOUNTED WIRELESS COMMUNICATION DEVICES HUMAN MODELS INSTRUMENTATION AND PROCEDURES PART 1 PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE SAR FOR HAND HELD DEVICES USED IN CLOSE PROXIMITY TO THE EAR FREQUENCY RANGE OF 300 MHZ TO 3 GHZ EN 62209 2 2010 HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND HELD AND BODY...

Page 164: ...alogic and the Datalogic logo are registered trademarks of Datalogic S p A In many countries including the U S A and the E U User s Manual Mobile Computer Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Telephone 39 051 3147011 Fax 39 051 3147561 Datalogic ADC S r l ...

Reviews: