ENTER/EXIT PROGRAMMING MODE
Codabar Minimum Reads
Product Reference Guide
201
Codabar Minimum Reads
This feature specifies the minimum number of consecutive times a Codabar label must be
decoded before it is accepted as good read.
Codabar Minimum Reads = 1
Codabar Minimum Reads = 2
DEFAULT
Codabar Minimum Reads = 3
Codabar Minimum Reads = 4