References
320
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the handheld reader and
Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of readers in the
same area). The selectable range for this feature is from 02 to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 25 =
25, etc
and scanScan the ENTER/EXIT PROGRAMMING MODE barcode to
enter Programming Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in
, that represent
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 46. STAR Radio Protocol Timeout Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Seconds
5 Seconds
10 Seconds
25 Seconds
2
Pad with leading zero(es)
02
05
10
25
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT INTERCODE DELAY SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘5’
‘1’ and ‘0’
‘2’ AND ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon BT4100
Page 56: ...ENTER EXIT PROGRAMMING MODE 54 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 288: ...Other BT Features 286 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 324: ...References 322 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 336: ...Technical Specifications 334 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 352: ...Sample Bar Codes 350 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 355: ...Keypad Product Reference Guide 353 A B C D E F ...
Page 356: ...Keypad 354 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 366: ...Scancode Tables 364 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...