Setup
Configuring the Base Station
26
Gryphon™ I GD44XX
/
GBT4400/GM440X
Linking the Reader to a Base Station
RF Devices
For RF devices, before configuring the interface it is necessary to link the handheld with the
base. To link the handheld and the base, press the trigger to wake it and place it on the base. If
the reader was previously linked to another base, you must first scan the Unlink action
command before re-linking to the new base.
BT Models only
Remember: The mandatory condition for establishing a new linking between a BT handheld
and a BT base is that the handheld is unlinked and they share the same security configuration. A
successful link is indicated by three ascending tones from the reader. A high-low-high-low tone
indicates the link attempt was unsuccessful. A single green LED flash after this tone indicates no
Base Station was discovered. Two green LED flashes after this tone indicates that more than one
Base Station was discovered and the reader did not link. Three LED flashes after this tone
indicate a security error.
Linking a BT Reader to a PC
The reader can optionally be linked to a Bluetooth-enabled PC with the serial port profile, in
either server mode or client mode.
Linking to a PC in Server Mode (BT Slave Mode)
To link a BT reader in server mode to a Bluetooth-enabled PC, follow these steps:
1. Install any drivers provided with the Bluetooth adapter.
2. Scan the
bar code below to make the scanner visible to the host computer.
3. Use the host computer’s Bluetooth manager to “Discover new devices” and select "Data-
logic Scanner." If you receive an error message, it may be necessary to disable security on
the device.
4. Select “connect” on the PC to link the reader to the PC. Use an RS-232 terminal program
to see incoming data on the port designated by the computer's Bluetooth manager.
Unlnk
Unlnk
³
L
n
k
S
v
Link to a PC in Server Mode
Summary of Contents for Gryphon I GBT4400
Page 42: ...Enter Exit Programming Mode Global Interface Features 40 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 56: ...Enter Exit Programming Mode RS 232 USB Com Interfaces 54 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 234: ...232 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 320: ...318 Gryphon I GD44XX GBT4400 GM440X A B C D E F...