References
278
Gryphon™ I GD44XX
/
GBT4400/GM440X
Stand Mode Off Time
This feature specifies the amount of time reader illumination stays off after pulling the trigger
when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms
to 16 seconds).
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 20 = 20,
etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to
enter Programming Mode.
4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5. Scan the appropriate two digits from the keypad in
, that represent
the setting which was determined in the steps above. You will hear a two-beep indication
after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 39. Stand Mode Off Time
STEP
ACTION
EXAMPLES
1
Desired Setting
500 ms
1 Second
5.5 Seconds
16 Seconds
2
Pad leading zero
01
02
11
32
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT STAND MODE OFF TIME
5
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘2’
‘1’ and ‘1’
‘3’ and ‘2’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon I GBT4400
Page 42: ...Enter Exit Programming Mode Global Interface Features 40 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 56: ...Enter Exit Programming Mode RS 232 USB Com Interfaces 54 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 234: ...232 Gryphon I GD44XX GBT4400 GM440X NOTES...