Codablock F
Product Reference Guide
249
Codablock F Set Length 1
This feature specifies one of the barcode lengths for
the minimum label length if in
Variable Length
Mode, or the first fixed length if in
Fixed
Length
Mode. Length includes the barcode’s data characters only.
The length can be set from 03 to 255 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 3 to 255). Pad the number with leading
zeroes to yield two digits. For example: 3 = 03, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODABLOCK F LENGTH 1 SETTING.
4. Scan the appropriate three digits from the keypad in the Keypad Appendix, that represent
the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See the table below for some examples of how to set this feature.
Table 25. CODABLOCK F Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
03 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABLOCK F LENGTH 1 SETTING
4
Scan Three Characters From the
Keypad Appendix
‘0’, ‘0’ and ‘3’
‘0’, ‘0’ and ‘7’
‘0’,‘1’ and ‘5’
‘0’,‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
Summary of Contents for Gryphon I GD4100
Page 14: ...Introduction 12 Gryphon I GD4100 GM4100 NOTES...
Page 34: ...Getting Started 32 Gryphon I GD4100 GM4100 NOTES...
Page 68: ...General Features 66 Gryphon I GD4100 GM4100 NOTES...
Page 80: ...RS 232 ONLY Interface 78 Gryphon I GD4100 GM4100 NOTES...
Page 100: ...RS 232 USB Com Interfaces 98 Gryphon I GD4100 GM4100 NOTES...
Page 118: ...USB OEM Interface 116 Gryphon I GD4100 GM4100 NOTES...
Page 130: ...Wand Emulation Interface 128 Gryphon I GD4100 GM4100 NOTES...
Page 154: ...Data Editing 152 Gryphon I GD4100 GM4100 NOTES...
Page 392: ...LED and Beeper Indications 390 Gryphon I GD4100 GM4100 NOTES...
Page 408: ...Sample Barcodes 406 Gryphon I GD4100 GM4100 NOTES...
Page 410: ...Keypad 408 Gryphon I GD4100 GM4100 6 7 8 9...
Page 411: ...Keypad Product Reference Guide 409 A B C D E F...
Page 412: ...Keypad 410 Gryphon I GD4100 GM4100 NOTES...
Page 422: ...420 Gryphon I GD4100 GM4100 IBM XT Table 60 Scancode Set When Control Character is 00 or 01...
Page 423: ...Product Reference Guide 421 IBM XT cont Table 61 Scancode Set When Control Character is 02...